PRODUCT DATASHEET
Please, use model selector above to see product datasheet.
PRODUCT DATASHEET
PS X2 PRECISION BALANCES - PS 10100.X2.M
| Readability [d] | 0,01g | 
|---|
| Maximum capacity [Max] |  | 
|---|
| Minimum load | 0,5g | 
|---|
| Repeatability (Max) | 0,012g | 
|---|
| Linearity | ±0,03g | 
|---|
| Stabilization time | 1,5s | 
|---|
| Sensitivity drift |  | 
|---|
| Operating temperature | +10 - +40°C | 
|---|
| Weighing pan dimensions | 195×195mm | 
|---|
| Power supply | 12 ÷ 16 V DC | 
|---|
| Display | 5" capacitive colour panel touchscreen | 
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Ethernet, Wireless Connection | 
|---|
| Packaging dimensions | 470×380×340mm | 
|---|
| Adjustment | internal (automatic) | 
|---|
| Net weight | 5,7kg | 
|---|
| Gross weight | 7,3kg | 
|---|
| Database capacity | 7 | 
|---|
| Atmospheric humidity | 40% ÷ 80% | 
|---|
| Repeatability (5% Max) | 0,005g | 
|---|
| Tare range | -10100g | 
|---|
| Minimum weight (USP) | 10g | 
|---|
| Minimum weight (U=1%,k=2) | 1g | 
|---|
| Power consumption | 4 W | 
|---|
| Touch-free operation | 2 IR Sensors | 
|---|
| Device dimensions | 333x206x107mm | 
|---|
| Net weight/gross weight |  | 
|---|
| OIML Class | - | 
|---|
| Operation time on batteries |  | 
|---|
| Preload range |  | 
|---|
| Protection class |  | 
|---|
| Repeatability |  | 
|---|
| Sensitivity tempr drift | 2×10⁻⁶/°C×Rt | 
|---|
| Storage temperature | -20 ÷ +50°C | 
|---|
| Verification scale interval | - | 
|---|
| Weight |  | 
|---|
| Verification | no | 
|---|
PRODUCT DATASHEET
PS X2 PRECISION BALANCES - PS 8100.X2.M
| Readability [d] | 0,01g | 
|---|
| Maximum capacity [Max] |  | 
|---|
| Minimum load | 0,5g | 
|---|
| Repeatability (Max) | 0,01g | 
|---|
| Linearity | ±0,03g | 
|---|
| Stabilization time | 1,5s | 
|---|
| Sensitivity drift |  | 
|---|
| Operating temperature | +10 - +40°C | 
|---|
| Weighing pan dimensions | 195×195mm | 
|---|
| Power supply | 12 ÷ 16 V DC | 
|---|
| Display | 5" capacitive colour panel touchscreen | 
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Ethernet, Wireless Connection | 
|---|
| Packaging dimensions | 470×380×336mm | 
|---|
| Adjustment | internal (automatic) | 
|---|
| Net weight | 5,7kg | 
|---|
| Gross weight | 7,3kg | 
|---|
| Database capacity | 7 | 
|---|
| Atmospheric humidity | 40% ÷ 80% | 
|---|
| Repeatability (5% Max) | 0,005g | 
|---|
| Tare range | -8100g | 
|---|
| Minimum weight (USP) | 10g | 
|---|
| Minimum weight (U=1%,k=2) | 1g | 
|---|
| Power consumption | 4 W | 
|---|
| Touch-free operation | 2 IR Sensors | 
|---|
| Device dimensions | 333x206x107 | 
|---|
| Net weight/gross weight |  | 
|---|
| OIML Class | II | 
|---|
| Operation time on batteries |  | 
|---|
| Preload range |  | 
|---|
| Protection class | IP 43 | 
|---|
| Repeatability |  | 
|---|
| Sensitivity tempr drift | 2×10⁻⁶/°C×Rt | 
|---|
| Storage temperature |  | 
|---|
| Verification scale interval | 0,1g | 
|---|
| Weight |  | 
|---|
| Verification | yes | 
|---|
PRODUCT DATASHEET
PS X2 PRECISION BALANCES - PS 6100.X2.M
| Readability [d] | 0,01g | 
|---|
| Maximum capacity [Max] |  | 
|---|
| Minimum load | 0,5g | 
|---|
| Repeatability (Max) | 0,008g | 
|---|
| Linearity | ±0,03g | 
|---|
| Stabilization time | 1,5s | 
|---|
| Sensitivity drift |  | 
|---|
| Operating temperature | +10 - +40°C | 
|---|
| Weighing pan dimensions | 195×195mm | 
|---|
| Power supply | 12 ÷ 16 V DC | 
|---|
| Display | 5" capacitive colour panel touchscreen | 
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Ethernet, Wireless Connection | 
|---|
| Packaging dimensions | 470×380×340mm | 
|---|
| Adjustment | internal (automatic) | 
|---|
| Net weight | 5,7kg | 
|---|
| Gross weight | 7,3kg | 
|---|
| Database capacity | 7 | 
|---|
| Atmospheric humidity | 40% ÷ 80% | 
|---|
| Repeatability (5% Max) | 0,005g | 
|---|
| Tare range | -6100g | 
|---|
| Minimum weight (USP) | 10g | 
|---|
| Minimum weight (U=1%,k=2) | 1g | 
|---|
| Power consumption | 4 W | 
|---|
| Touch-free operation | 2 IR Sensors | 
|---|
| Device dimensions | 333x206x107 | 
|---|
| Net weight/gross weight |  | 
|---|
| OIML Class | II | 
|---|
| Operation time on batteries |  | 
|---|
| Preload range |  | 
|---|
| Protection class | IP 43 | 
|---|
| Repeatability |  | 
|---|
| Sensitivity tempr drift | 2×10⁻⁶/°C×Rt | 
|---|
| Storage temperature | -20 ÷ +50°C | 
|---|
| Verification scale interval | 0,1g | 
|---|
| Weight |  | 
|---|
| Verification | yes | 
|---|
PRODUCT DATASHEET
PS X2 PRECISION BALANCES - PS 4500.X2.M
| Readability [d] | 0,01g | 
|---|
| Maximum capacity [Max] |  | 
|---|
| Minimum load | 0,5g | 
|---|
| Repeatability (Max) | 0,008g | 
|---|
| Linearity | ±0,03g | 
|---|
| Stabilization time | 1,5s | 
|---|
| Sensitivity drift |  | 
|---|
| Operating temperature | +10 - +40°C | 
|---|
| Weighing pan dimensions | 195×195mm | 
|---|
| Power supply | 12 ÷ 16 V DC | 
|---|
| Display | 5" capacitive colour panel touchscreen | 
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Ethernet, Wireless Connection | 
|---|
| Packaging dimensions | 470×380×340mm | 
|---|
| Adjustment | internal (automatic) | 
|---|
| Net weight | 4,5kg | 
|---|
| Gross weight | 6,1kg | 
|---|
| Database capacity | 7 | 
|---|
| Atmospheric humidity | 40% ÷ 80% | 
|---|
| Repeatability (5% Max) | 0,005g | 
|---|
| Tare range | -4500g | 
|---|
| Minimum weight (USP) | 10g | 
|---|
| Minimum weight (U=1%,k=2) | 1g | 
|---|
| Power consumption | 4 W | 
|---|
| Touch-free operation | 2 IR Sensors | 
|---|
| Device dimensions | 333x206x107mm | 
|---|
| Net weight/gross weight |  | 
|---|
| OIML Class | II | 
|---|
| Operation time on batteries |  | 
|---|
| Preload range |  | 
|---|
| Protection class | IP 43 | 
|---|
| Repeatability |  | 
|---|
| Sensitivity tempr drift | 2×10⁻⁶/°C×Rt | 
|---|
| Storage temperature | -20 ÷ +50°C | 
|---|
| Verification scale interval | 0,1g | 
|---|
| Weight |  | 
|---|
| Verification | yes | 
|---|
PRODUCT DATASHEET
PS X2 PRECISION BALANCES - PS 3500.X2
| Readability [d] | 0,01g | 
|---|
| Maximum capacity [Max] |  | 
|---|
| Minimum load | 0,5g | 
|---|
| Repeatability (Max) | 0,01g | 
|---|
| Linearity | ±0,02g | 
|---|
| Stabilization time | 1,5s | 
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C | 
|---|
| Operating temperature | +10 - +40°C | 
|---|
| Weighing pan dimensions | 195×195mm | 
|---|
| Power supply | 12 ÷ 16 V DC | 
|---|
| Display | 5" capacitive colour panel touchscreen | 
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Ethernet, Wireless Connection | 
|---|
| Packaging dimensions | 470×380×336mm | 
|---|
| Adjustment | internal (automatic) | 
|---|
| Net weight | 4,5kg | 
|---|
| Gross weight | 6kg | 
|---|
| Database capacity | 7 | 
|---|
| Atmospheric humidity |  | 
|---|
| Repeatability (5% Max) | 0,005g | 
|---|
| Tare range | -3500g | 
|---|
| Minimum weight (USP) | 10g | 
|---|
| Minimum weight (U=1%,k=2) | 1g | 
|---|
| Power consumption | 250 mA | 
|---|
| Touch-free operation | 2 IR Sensors | 
|---|
| Device dimensions |  | 
|---|
| Net weight/gross weight |  | 
|---|
| OIML Class |  | 
|---|
| Operation time on batteries |  | 
|---|
| Preload range |  | 
|---|
| Protection class |  | 
|---|
| Repeatability |  | 
|---|
| Sensitivity tempr drift |  | 
|---|
| Storage temperature |  | 
|---|
| Verification scale interval |  | 
|---|
| Weight |  | 
|---|
| Verification | yes | 
|---|
PRODUCT DATASHEET
PS X2 PRECISION BALANCES - PS 3000.X2
| Readability [d] | 0,001g | 
|---|
| Maximum capacity [Max] |  | 
|---|
| Minimum load | 0,02g | 
|---|
| Repeatability (Max) | 0,001g | 
|---|
| Linearity | ±0,004g | 
|---|
| Stabilization time | 3s | 
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C | 
|---|
| Operating temperature | +10 - +40°C | 
|---|
| Weighing pan dimensions | 128×128mm | 
|---|
| Power supply | 12 ÷ 16 V DC | 
|---|
| Display | 5" capacitive colour panel touchscreen | 
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Ethernet, Wireless Connection | 
|---|
| Packaging dimensions | 470×380×336mm | 
|---|
| Adjustment | internal (automatic) | 
|---|
| Net weight | 3,9kg | 
|---|
| Gross weight | 5,5kg | 
|---|
| Database capacity | 7 | 
|---|
| Atmospheric humidity |  | 
|---|
| Repeatability (5% Max) | 0,0005g | 
|---|
| Tare range | -3000g | 
|---|
| Minimum weight (USP) | 1g | 
|---|
| Minimum weight (U=1%,k=2) | 0,1g | 
|---|
| Power consumption | 250 mA | 
|---|
| Touch-free operation | 2 IR Sensors | 
|---|
| Device dimensions |  | 
|---|
| Net weight/gross weight |  | 
|---|
| OIML Class |  | 
|---|
| Operation time on batteries |  | 
|---|
| Preload range |  | 
|---|
| Protection class |  | 
|---|
| Repeatability |  | 
|---|
| Sensitivity tempr drift |  | 
|---|
| Storage temperature |  | 
|---|
| Verification scale interval |  | 
|---|
| Weight |  | 
|---|
| Verification | no | 
|---|
PRODUCT DATASHEET
PS X2 PRECISION BALANCES - PS 2100.X2
| Readability [d] | 0,01g | 
|---|
| Maximum capacity [Max] |  | 
|---|
| Minimum load | 0,5g | 
|---|
| Repeatability (Max) | 0,01g | 
|---|
| Linearity | ±0,02g | 
|---|
| Stabilization time | 1,5s | 
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C | 
|---|
| Operating temperature | +10 - +40°C | 
|---|
| Weighing pan dimensions | 195×195mm | 
|---|
| Power supply | 12 ÷ 16 V DC | 
|---|
| Display | 5" capacitive colour panel touchscreen | 
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Ethernet, Wireless Connection | 
|---|
| Packaging dimensions | 470×380×336mm | 
|---|
| Adjustment | internal (automatic) | 
|---|
| Net weight | 4,3kg | 
|---|
| Gross weight | 5,8kg | 
|---|
| Database capacity | 7 | 
|---|
| Atmospheric humidity |  | 
|---|
| Repeatability (5% Max) | 0,005g | 
|---|
| Tare range | -2100g | 
|---|
| Minimum weight (USP) | 10g | 
|---|
| Minimum weight (U=1%,k=2) | 1g | 
|---|
| Power consumption | 250 mA | 
|---|
| Touch-free operation | 2 IR Sensors | 
|---|
| Device dimensions |  | 
|---|
| Net weight/gross weight |  | 
|---|
| OIML Class |  | 
|---|
| Operation time on batteries |  | 
|---|
| Preload range |  | 
|---|
| Protection class |  | 
|---|
| Repeatability |  | 
|---|
| Sensitivity tempr drift |  | 
|---|
| Storage temperature |  | 
|---|
| Verification scale interval |  | 
|---|
| Weight |  | 
|---|
| Verification | yes | 
|---|
PRODUCT DATASHEET
PS X2 PRECISION BALANCES - PS 1200.X2
| Readability [d] | 0,01g | 
|---|
| Maximum capacity [Max] |  | 
|---|
| Minimum load | 0,5g | 
|---|
| Repeatability (Max) | 0,01g | 
|---|
| Linearity | ±0,02g | 
|---|
| Stabilization time | 1,5s | 
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C | 
|---|
| Operating temperature | +10 - +40°C | 
|---|
| Weighing pan dimensions | 195×195mm | 
|---|
| Power supply | 12 ÷ 16 V DC | 
|---|
| Display | 5" capacitive colour panel touchscreen | 
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Ethernet, Wireless Connection | 
|---|
| Packaging dimensions | 470×380×336mm | 
|---|
| Adjustment | internal (automatic) | 
|---|
| Net weight | 4,3kg | 
|---|
| Gross weight | 5,8kg | 
|---|
| Database capacity | 7 | 
|---|
| Atmospheric humidity |  | 
|---|
| Repeatability (5% Max) | 0,005g | 
|---|
| Tare range | -1200g | 
|---|
| Minimum weight (USP) | 10g | 
|---|
| Minimum weight (U=1%,k=2) | 1g | 
|---|
| Power consumption | 250 mA | 
|---|
| Touch-free operation | 2 IR Sensors | 
|---|
| Device dimensions |  | 
|---|
| Net weight/gross weight |  | 
|---|
| OIML Class |  | 
|---|
| Operation time on batteries |  | 
|---|
| Preload range |  | 
|---|
| Protection class |  | 
|---|
| Repeatability |  | 
|---|
| Sensitivity tempr drift |  | 
|---|
| Storage temperature |  | 
|---|
| Verification scale interval |  | 
|---|
| Weight |  | 
|---|
| Verification | yes | 
|---|
PRODUCT DATASHEET
PS X2 PRECISION BALANCES - PS 1000.X2
| Readability [d] | 0,001g | 
|---|
| Maximum capacity [Max] |  | 
|---|
| Minimum load | 0,02g | 
|---|
| Repeatability (Max) | 0,0015g | 
|---|
| Linearity | ±0,003g | 
|---|
| Stabilization time | 2s | 
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C | 
|---|
| Operating temperature | +10 - +40°C | 
|---|
| Weighing pan dimensions | 128×128mm | 
|---|
| Power supply | 12 ÷ 16 V DC | 
|---|
| Display | 5" capacitive colour panel touchscreen | 
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Ethernet, Wireless Connection | 
|---|
| Packaging dimensions | 470×380×336mm | 
|---|
| Adjustment | internal (automatic) | 
|---|
| Net weight | 3,9kg | 
|---|
| Gross weight | 5,5kg | 
|---|
| Database capacity | 7 | 
|---|
| Atmospheric humidity |  | 
|---|
| Repeatability (5% Max) | 0,0005g | 
|---|
| Tare range | -1000g | 
|---|
| Minimum weight (USP) | 1g | 
|---|
| Minimum weight (U=1%,k=2) | 0,1g | 
|---|
| Power consumption | 250 mA | 
|---|
| Touch-free operation | 2 IR Sensors | 
|---|
| Device dimensions |  | 
|---|
| Net weight/gross weight |  | 
|---|
| OIML Class |  | 
|---|
| Operation time on batteries |  | 
|---|
| Preload range |  | 
|---|
| Protection class |  | 
|---|
| Repeatability |  | 
|---|
| Sensitivity tempr drift |  | 
|---|
| Storage temperature |  | 
|---|
| Verification scale interval |  | 
|---|
| Weight |  | 
|---|
| Verification | yes | 
|---|
PRODUCT DATASHEET
PS X2 PRECISION BALANCES - PS 750.X2
| Readability [d] | 0,001g | 
|---|
| Maximum capacity [Max] |  | 
|---|
| Minimum load | 0,02g | 
|---|
| Repeatability (Max) | 0,0015g | 
|---|
| Linearity | ±0,003g | 
|---|
| Stabilization time | 2s | 
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C | 
|---|
| Operating temperature | +10 - +40°C | 
|---|
| Weighing pan dimensions | 128×128mm | 
|---|
| Power supply | 12 ÷ 16 V DC | 
|---|
| Display | 5" capacitive colour panel touchscreen | 
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Ethernet, Wireless Connection | 
|---|
| Packaging dimensions | 470×380×336mm | 
|---|
| Adjustment | internal (automatic) | 
|---|
| Net weight | 3,9kg | 
|---|
| Gross weight | 5,5kg | 
|---|
| Database capacity | 7 | 
|---|
| Atmospheric humidity |  | 
|---|
| Repeatability (5% Max) | 0,0005g | 
|---|
| Tare range | -750g | 
|---|
| Minimum weight (USP) | 1g | 
|---|
| Minimum weight (U=1%,k=2) | 0,1g | 
|---|
| Power consumption | 250 mA | 
|---|
| Touch-free operation | 2 IR Sensors | 
|---|
| Device dimensions |  | 
|---|
| Net weight/gross weight |  | 
|---|
| OIML Class |  | 
|---|
| Operation time on batteries |  | 
|---|
| Preload range |  | 
|---|
| Protection class |  | 
|---|
| Repeatability |  | 
|---|
| Sensitivity tempr drift |  | 
|---|
| Storage temperature |  | 
|---|
| Verification scale interval |  | 
|---|
| Weight |  | 
|---|
| Verification | yes | 
|---|
PRODUCT DATASHEET
PS X2 PRECISION BALANCES - PS 600.X2
| Readability [d] | 0,001g | 
|---|
| Maximum capacity [Max] |  | 
|---|
| Minimum load | 0,02g | 
|---|
| Repeatability (Max) | 0,0015g | 
|---|
| Linearity | ±0,003g | 
|---|
| Stabilization time | 2s | 
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C | 
|---|
| Operating temperature | +10 - +40°C | 
|---|
| Weighing pan dimensions | 128×128mm | 
|---|
| Power supply | 12 ÷ 16 V DC | 
|---|
| Display | 5" capacitive colour panel touchscreen | 
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Ethernet, Wireless Connection | 
|---|
| Packaging dimensions | 470×380×336mm | 
|---|
| Adjustment | internal (automatic) | 
|---|
| Net weight | 3,9kg | 
|---|
| Gross weight | 5,5kg | 
|---|
| Database capacity | 7 | 
|---|
| Atmospheric humidity |  | 
|---|
| Repeatability (5% Max) | 0,0005g | 
|---|
| Tare range | -600g | 
|---|
| Minimum weight (USP) | 1g | 
|---|
| Minimum weight (U=1%,k=2) | 0,1g | 
|---|
| Power consumption | 250 mA | 
|---|
| Touch-free operation | 2 IR Sensors | 
|---|
| Device dimensions |  | 
|---|
| Net weight/gross weight |  | 
|---|
| OIML Class |  | 
|---|
| Operation time on batteries |  | 
|---|
| Preload range |  | 
|---|
| Protection class |  | 
|---|
| Repeatability |  | 
|---|
| Sensitivity tempr drift |  | 
|---|
| Storage temperature |  | 
|---|
| Verification scale interval |  | 
|---|
| Weight |  | 
|---|
| Verification | yes | 
|---|
PRODUCT DATASHEET
PS X2 PRECISION BALANCES - PS 360.X2
| Readability [d] | 0,001g | 
|---|
| Maximum capacity [Max] |  | 
|---|
| Minimum load | 0,02g | 
|---|
| Repeatability (Max) | 0,001g | 
|---|
| Linearity | ±0,002g | 
|---|
| Stabilization time | 2s | 
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C | 
|---|
| Operating temperature | +10 - +40°C | 
|---|
| Weighing pan dimensions | 128×128mm | 
|---|
| Power supply | 12 ÷ 16 V DC | 
|---|
| Display | 5" capacitive colour panel touchscreen | 
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Ethernet, Wireless Connection | 
|---|
| Packaging dimensions | 470×380×336mm | 
|---|
| Adjustment | internal (automatic) | 
|---|
| Net weight | 3,7kg | 
|---|
| Gross weight | 5,3kg | 
|---|
| Database capacity | 7 | 
|---|
| Atmospheric humidity |  | 
|---|
| Repeatability (5% Max) | 0,0005g | 
|---|
| Tare range | -360g | 
|---|
| Minimum weight (USP) | 1g | 
|---|
| Minimum weight (U=1%,k=2) | 0,1g | 
|---|
| Power consumption | 250 mA | 
|---|
| Touch-free operation | 2 IR Sensors | 
|---|
| Device dimensions |  | 
|---|
| Net weight/gross weight |  | 
|---|
| OIML Class |  | 
|---|
| Operation time on batteries |  | 
|---|
| Preload range |  | 
|---|
| Protection class |  | 
|---|
| Repeatability |  | 
|---|
| Sensitivity tempr drift |  | 
|---|
| Storage temperature |  | 
|---|
| Verification scale interval |  | 
|---|
| Weight |  | 
|---|
| Verification | yes | 
|---|
PRODUCT DATASHEET
PS X2 PRECISION BALANCES - PS 210.X2
| Readability [d] | 0,001g | 
|---|
| Maximum capacity [Max] |  | 
|---|
| Minimum load | 0,02g | 
|---|
| Repeatability (Max) | 0,001g | 
|---|
| Linearity | ±0,002g | 
|---|
| Stabilization time | 2s | 
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C | 
|---|
| Operating temperature | +10 - +40°C | 
|---|
| Weighing pan dimensions | 128×128mm | 
|---|
| Power supply | 12 ÷ 16 V DC | 
|---|
| Display | 5" capacitive colour panel touchscreen | 
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Ethernet, Wireless Connection | 
|---|
| Packaging dimensions | 470×380×336mm | 
|---|
| Adjustment | internal (automatic) | 
|---|
| Net weight |  | 
|---|
| Gross weight |  | 
|---|
| Database capacity |  | 
|---|
| Atmospheric humidity |  | 
|---|
| Repeatability (5% Max) |  | 
|---|
| Tare range |  | 
|---|
| Minimum weight (USP) |  | 
|---|
| Minimum weight (U=1%,k=2) |  | 
|---|
| Power consumption |  | 
|---|
| Touch-free operation |  | 
|---|
| Device dimensions |  | 
|---|
| Net weight/gross weight |  | 
|---|
| OIML Class |  | 
|---|
| Operation time on batteries |  | 
|---|
| Preload range |  | 
|---|
| Protection class |  | 
|---|
| Repeatability |  | 
|---|
| Sensitivity tempr drift |  | 
|---|
| Storage temperature |  | 
|---|
| Verification scale interval |  | 
|---|
| Weight |  | 
|---|
| Verification | yes | 
|---|
PRODUCT DATASHEET
PS X2 PRECISION BALANCES - PS 200/2000.X2
| Readability [d] | 0,001/0,01g | 
|---|
| Maximum capacity [Max] |  | 
|---|
| Minimum load | 0,02g | 
|---|
| Repeatability (Max) | 0,001/0,01g | 
|---|
| Linearity | ±0,002/0,02g | 
|---|
| Stabilization time | 2/1,5s | 
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C | 
|---|
| Operating temperature | +10 - +40°C | 
|---|
| Weighing pan dimensions | 128×128mm | 
|---|
| Power supply | 12 ÷ 16 V DC | 
|---|
| Display | 5" capacitive colour panel touchscreen | 
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Ethernet, Wireless Connection | 
|---|
| Packaging dimensions | 470×380×336mm | 
|---|
| Adjustment | internal (automatic) | 
|---|
| Net weight | 3,9kg | 
|---|
| Gross weight | 5,5kg | 
|---|
| Database capacity | 7 | 
|---|
| Atmospheric humidity |  | 
|---|
| Repeatability (5% Max) | 0,0005/0,005g | 
|---|
| Tare range | -2000g | 
|---|
| Minimum weight (USP) | 1g | 
|---|
| Minimum weight (U=1%,k=2) | 0,1g | 
|---|
| Power consumption | 250 mA | 
|---|
| Touch-free operation | 2 IR Sensors | 
|---|
| Device dimensions |  | 
|---|
| Net weight/gross weight |  | 
|---|
| OIML Class |  | 
|---|
| Operation time on batteries |  | 
|---|
| Preload range |  | 
|---|
| Protection class |  | 
|---|
| Repeatability |  | 
|---|
| Sensitivity tempr drift |  | 
|---|
| Storage temperature |  | 
|---|
| Verification scale interval |  | 
|---|
| Weight |  | 
|---|
| Verification | yes | 
|---|