PRODUCT DATASHEET
Please, use model selector above to see product datasheet.
PRODUCT DATASHEET
PS R2.H PRECISION BALANCES - PS 200/2000.R2.H
| Readability [d] | 0,001/0,01g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 20mg |
|---|
| Repeatability (Max) | 0,001/0,01g |
|---|
| Linearity | ±0,002/0,02g |
|---|
| Stabilization time | 2/1,5s |
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C |
|---|
| Operating temperature | +10 - +40°C |
|---|
| Weighing pan dimensions | ø115mm |
|---|
| Power supply | 12 ÷ 16 V DC |
|---|
| Display | LCD (backlit) |
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Wireless Connection (option) |
|---|
| Packaging dimensions | 470×380×336mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | |
|---|
| Gross weight | |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,0005/0,005g |
|---|
| Tare range | -2000g |
|---|
| Minimum weight (USP) | |
|---|
| Minimum weight (U=1%,k=2) | |
|---|
| Power consumption | |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | 4,5/6,5kg |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | no |
|---|
PRODUCT DATASHEET
PS R2.H PRECISION BALANCES - PS 210.R2.H
| Readability [d] | 0,001g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 20mg |
|---|
| Repeatability (Max) | 0,001g |
|---|
| Linearity | ±0,002g |
|---|
| Stabilization time | 2s |
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C |
|---|
| Operating temperature | +10 - +40°C |
|---|
| Weighing pan dimensions | ø115mm |
|---|
| Power supply | 12 ÷ 16 V DC |
|---|
| Display | LCD (backlit) |
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Wireless Connection (option) |
|---|
| Packaging dimensions | 470×380×336mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | |
|---|
| Gross weight | |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,0005g |
|---|
| Tare range | -210g |
|---|
| Minimum weight (USP) | |
|---|
| Minimum weight (U=1%,k=2) | |
|---|
| Power consumption | |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | 4,2/6,2kg |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | no |
|---|
PRODUCT DATASHEET
PS R2.H PRECISION BALANCES - PS 360.R2.H
| Readability [d] | 0,001g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 20mg |
|---|
| Repeatability (Max) | 0,001g |
|---|
| Linearity | ±0,002g |
|---|
| Stabilization time | 2s |
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C |
|---|
| Operating temperature | +10 - +40°C |
|---|
| Weighing pan dimensions | ø115mm |
|---|
| Power supply | 12 ÷ 16 V DC |
|---|
| Display | LCD (backlit) |
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Wireless Connection (option) |
|---|
| Packaging dimensions | 470×380×336mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | |
|---|
| Gross weight | |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,0005g |
|---|
| Tare range | -360g |
|---|
| Minimum weight (USP) | |
|---|
| Minimum weight (U=1%,k=2) | |
|---|
| Power consumption | |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | 4,2/6,2kg |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | no |
|---|
PRODUCT DATASHEET
PS R2.H PRECISION BALANCES - PS 600.R2.H
| Readability [d] | 0,001g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 20mg |
|---|
| Repeatability (Max) | 0,0015g |
|---|
| Linearity | ±0,003g |
|---|
| Stabilization time | 2s |
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C |
|---|
| Operating temperature | +10 - +40°C |
|---|
| Weighing pan dimensions | ø115mm |
|---|
| Power supply | 12 ÷ 16 V DC |
|---|
| Display | LCD (backlit) |
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Wireless Connection (option) |
|---|
| Packaging dimensions | 470×380×336mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | |
|---|
| Gross weight | |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,0005g |
|---|
| Tare range | -600g |
|---|
| Minimum weight (USP) | |
|---|
| Minimum weight (U=1%,k=2) | |
|---|
| Power consumption | |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | 4,3/6,3kg |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | no |
|---|
PRODUCT DATASHEET
PS R2.H PRECISION BALANCES - PS 750.R2.H
| Readability [d] | 0,001g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 20mg |
|---|
| Repeatability (Max) | 0,0015g |
|---|
| Linearity | ±0,003g |
|---|
| Stabilization time | 2s |
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C |
|---|
| Operating temperature | +10 - +40°C |
|---|
| Weighing pan dimensions | ø115mm |
|---|
| Power supply | 12 ÷ 16 V DC |
|---|
| Display | LCD (backlit) |
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Wireless Connection (option) |
|---|
| Packaging dimensions | 470×380×336mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | |
|---|
| Gross weight | |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,0005g |
|---|
| Tare range | -750g |
|---|
| Minimum weight (USP) | |
|---|
| Minimum weight (U=1%,k=2) | |
|---|
| Power consumption | |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | 3,5/5,5kg |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | no |
|---|
PRODUCT DATASHEET
PS R2.H PRECISION BALANCES - PS 1000.R2.H
| Readability [d] | 0,001g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 20mg |
|---|
| Repeatability (Max) | 0,0015g |
|---|
| Linearity | ±0,003g |
|---|
| Stabilization time | 2s |
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C |
|---|
| Operating temperature | +10 - +40°C |
|---|
| Weighing pan dimensions | ø115mm |
|---|
| Power supply | 12 ÷ 16 V DC |
|---|
| Display | LCD (backlit) |
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Wireless Connection (option) |
|---|
| Packaging dimensions | 470×380×336mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | |
|---|
| Gross weight | |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,0005g |
|---|
| Tare range | -1000g |
|---|
| Minimum weight (USP) | |
|---|
| Minimum weight (U=1%,k=2) | |
|---|
| Power consumption | |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | 4,5/6,5kg |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | no |
|---|
PRODUCT DATASHEET
PS R2.H PRECISION BALANCES - PS 1200.R2.H
| Readability [d] | 0,01g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 500mg |
|---|
| Repeatability (Max) | 0,01g |
|---|
| Linearity | ±0,02g |
|---|
| Stabilization time | 1,5s |
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C |
|---|
| Operating temperature | +10 - +40°C |
|---|
| Weighing pan dimensions | ø170mm |
|---|
| Power supply | 12 ÷ 16 V DC |
|---|
| Display | LCD (backlit) |
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Wireless Connection (option) |
|---|
| Packaging dimensions | 470×380×336mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | |
|---|
| Gross weight | |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,005g |
|---|
| Tare range | -1200g |
|---|
| Minimum weight (USP) | |
|---|
| Minimum weight (U=1%,k=2) | |
|---|
| Power consumption | |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | 4,3/5,8kg |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | no |
|---|
PRODUCT DATASHEET
PS R2.H PRECISION BALANCES - PS 2100.R2.H
| Readability [d] | 0,01g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 500mg |
|---|
| Repeatability (Max) | 0,01g |
|---|
| Linearity | ±0,02g |
|---|
| Stabilization time | 1,5s |
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C |
|---|
| Operating temperature | +10 - +40°C |
|---|
| Weighing pan dimensions | ø170mm |
|---|
| Power supply | 12 ÷ 16 V DC |
|---|
| Display | LCD (backlit) |
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Wireless Connection (option) |
|---|
| Packaging dimensions | 470×380×336mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | |
|---|
| Gross weight | |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,005g |
|---|
| Tare range | -2100g |
|---|
| Minimum weight (USP) | |
|---|
| Minimum weight (U=1%,k=2) | |
|---|
| Power consumption | |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | 3,6/5,1kg |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | no |
|---|
PRODUCT DATASHEET
PS R2.H PRECISION BALANCES - PS 3500.R2.H
| Readability [d] | 0,01g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 500mg |
|---|
| Repeatability (Max) | 0,01g |
|---|
| Linearity | ±0,02g |
|---|
| Stabilization time | 1,5s |
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C |
|---|
| Operating temperature | +10 - +40°C |
|---|
| Weighing pan dimensions | ø170mm |
|---|
| Power supply | 12 ÷ 16 V DC |
|---|
| Display | LCD (backlit) |
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Wireless Connection (option) |
|---|
| Packaging dimensions | 470×380×336mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | |
|---|
| Gross weight | |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,005g |
|---|
| Tare range | -3500g |
|---|
| Minimum weight (USP) | |
|---|
| Minimum weight (U=1%,k=2) | |
|---|
| Power consumption | |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | 3,6/5,1kg |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | no |
|---|
PRODUCT DATASHEET
PS R2.H PRECISION BALANCES - PS 4500.R2.H
| Readability [d] | 0,01g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 500mg |
|---|
| Repeatability (Max) | 0,01g |
|---|
| Linearity | ±0,02g |
|---|
| Stabilization time | 1,5s |
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C |
|---|
| Operating temperature | +10 - +40°C |
|---|
| Weighing pan dimensions | ø170mm |
|---|
| Power supply | 12 ÷ 16 V DC |
|---|
| Display | LCD (backlit) |
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Wireless Connection (option) |
|---|
| Packaging dimensions | 470×380×336mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | |
|---|
| Gross weight | |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,005g |
|---|
| Tare range | -4500g |
|---|
| Minimum weight (USP) | |
|---|
| Minimum weight (U=1%,k=2) | |
|---|
| Power consumption | |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | 4,8/6,3kg |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | no |
|---|
PRODUCT DATASHEET
PS R2.H PRECISION BALANCES - PS 6000.R2.H
| Readability [d] | 0,01g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 500mg |
|---|
| Repeatability (Max) | 0,015g |
|---|
| Linearity | ±0,03g |
|---|
| Stabilization time | 1,5s |
|---|
| Sensitivity drift | 2 ppm/°C in temperature +10 - +40°C |
|---|
| Operating temperature | +10 - +40°C |
|---|
| Weighing pan dimensions | ø170mm |
|---|
| Power supply | 12 ÷ 16 V DC |
|---|
| Display | LCD (backlit) |
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Wireless Connection (option) |
|---|
| Packaging dimensions | 470×380×336mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | |
|---|
| Gross weight | |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,005g |
|---|
| Tare range | -6000g |
|---|
| Minimum weight (USP) | |
|---|
| Minimum weight (U=1%,k=2) | |
|---|
| Power consumption | |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | 4,8/6,3kg |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | no |
|---|