PRODUCT DATASHEET
Please, use model selector above to see product datasheet.
PRODUCT DATASHEET
PS 3Y PRECISION BALANCES - PS 10100.3Y.M
| Readability [d] | 0,01g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 500mg |
|---|
| Repeatability (Max) | 0,012g |
|---|
| Linearity | ±0,03g |
|---|
| Stabilization time | 1,5s |
|---|
| Sensitivity drift | 2ppm/°C in temperature +15 ÷ +35°C |
|---|
| Operating temperature | +10 ÷ +40°C |
|---|
| Weighing pan dimensions | 195×195mm |
|---|
| Power supply | 13,5 ÷ 16 V DC |
|---|
| Display | 5,7'' (panel touchscreen) |
|---|
| Communication interface | 2×USB, 2×RS 232, Ethernet, 4Inputs/4Outputs (digital), Wireless Connection |
|---|
| Packaging dimensions | 716×360×260mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | 6,8kg |
|---|
| Gross weight | 9,4kg |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,005g |
|---|
| Tare range | -10100g |
|---|
| Minimum weight (USP) | 10g |
|---|
| Minimum weight (U=1%,k=2) | 1g |
|---|
| Power consumption | 500mA (wireless terminal - 1A) |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | no |
|---|
PRODUCT DATASHEET
PS 3Y PRECISION BALANCES - PS 8100.3Y.M
| Readability [d] | 0,01g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 500mg |
|---|
| Repeatability (Max) | 0,01g |
|---|
| Linearity | ±0,03g |
|---|
| Stabilization time | 1,5s |
|---|
| Sensitivity drift | 2ppm/°C in temperature +15 ÷ +35°C |
|---|
| Operating temperature | +10 ÷ +40°C |
|---|
| Weighing pan dimensions | 195×195mm |
|---|
| Power supply | 13,5 ÷ 16 V DC |
|---|
| Display | 5,7'' (panel touchscreen) |
|---|
| Communication interface | 2×USB, 2×RS 232, Ethernet, 4Inputs/4Outputs (digital), Wireless Connection |
|---|
| Packaging dimensions | 716×360×260mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | 6,8kg |
|---|
| Gross weight | 9,4kg |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,005g |
|---|
| Tare range | -8100g |
|---|
| Minimum weight (USP) | 10g |
|---|
| Minimum weight (U=1%,k=2) | 1g |
|---|
| Power consumption | 500mA (wireless terminal - 1A) |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | yes |
|---|
PRODUCT DATASHEET
PS 3Y PRECISION BALANCES - PS 6100.3Y.M
| Readability [d] | 0,01g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 500mg |
|---|
| Repeatability (Max) | 0,008g |
|---|
| Linearity | ±0,03g |
|---|
| Stabilization time | 1,5s |
|---|
| Sensitivity drift | 2ppm/°C in temperature +15 ÷ +35°C |
|---|
| Operating temperature | +10 ÷ +40°C |
|---|
| Weighing pan dimensions | 195×195mm |
|---|
| Power supply | 13,5 ÷ 16 V DC |
|---|
| Display | 5,7'' (panel touchscreen) |
|---|
| Communication interface | 2×USB, 2×RS 232, Ethernet, 4Inputs/4Outputs (digital), Wireless Connection |
|---|
| Packaging dimensions | 716×360×260mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | 6,8kg |
|---|
| Gross weight | 9,4kg |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,005g |
|---|
| Tare range | -6100g |
|---|
| Minimum weight (USP) | 10g |
|---|
| Minimum weight (U=1%,k=2) | 1g |
|---|
| Power consumption | 500mA (wireless terminal - 1A) |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | yes |
|---|
PRODUCT DATASHEET
PS 3Y PRECISION BALANCES - PS 4500.3Y.M
| Readability [d] | 0,01g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 0,5g |
|---|
| Repeatability (Max) | 0,008g |
|---|
| Linearity | ±0,03g |
|---|
| Stabilization time | 1,5s |
|---|
| Sensitivity drift | |
|---|
| Operating temperature | +10 ÷ +40°C |
|---|
| Weighing pan dimensions | 195×195mm |
|---|
| Power supply | 13,5 ÷ 16 V DC |
|---|
| Display | 5,7'' (panel touchscreen) |
|---|
| Communication interface | 2×USB, 2×RS 232, Ethernet, 4Inputs/4Outputs (digital), Wireless Connection |
|---|
| Packaging dimensions | 716×360×260mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | 5,6kg |
|---|
| Gross weight | 8,2kg |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,005g |
|---|
| Tare range | -4500g |
|---|
| Minimum weight (USP) | 10g |
|---|
| Minimum weight (U=1%,k=2) | 1g |
|---|
| Power consumption | 4 W |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | yes |
|---|
PRODUCT DATASHEET
PS 3Y PRECISION BALANCES - PS 3000.3Y
| Readability [d] | 0,001g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 20mg |
|---|
| Repeatability (Max) | 0,0015g |
|---|
| Linearity | ±0,004g |
|---|
| Stabilization time | 3s |
|---|
| Sensitivity drift | 2ppm/°C in temperature +15 ÷ +35°C |
|---|
| Operating temperature | +10 ÷ +40°C |
|---|
| Weighing pan dimensions | 128×128mm |
|---|
| Power supply | 13,5 ÷ 16 V DC |
|---|
| Display | 5,7'' (panel touchscreen) |
|---|
| Communication interface | 2×USB, 2×RS 232, Ethernet, 4Inputs/4Outputs (digital), Wireless Connection |
|---|
| Packaging dimensions | 716×360×260mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | 5,7kg |
|---|
| Gross weight | 8,3kg |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,0005g |
|---|
| Tare range | -3000g |
|---|
| Minimum weight (USP) | 1g |
|---|
| Minimum weight (U=1%,k=2) | 0,1g |
|---|
| Power consumption | 500mA (wireless terminal - 1A) |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | no |
|---|
PRODUCT DATASHEET
PS 3Y PRECISION BALANCES - PS 2500.3Y
| Readability [d] | 10mg |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 500mg |
|---|
| Repeatability (Max) | |
|---|
| Linearity | ±0,02g |
|---|
| Stabilization time | 1,5s |
|---|
| Sensitivity drift | 2ppm/°C in temperature +15 ÷ +35°C |
|---|
| Operating temperature | +10 ÷ +40°C |
|---|
| Weighing pan dimensions | 195×195mm |
|---|
| Power supply | 13,5 ÷ 16 V DC |
|---|
| Display | 5,7'' (panel touchscreen) |
|---|
| Communication interface | 2×USB, 2×RS 232, Ethernet, 4Inputs/4Outputs (digital), Wireless Connection |
|---|
| Packaging dimensions | 716×360×260mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | 5,6kg |
|---|
| Gross weight | 8,2kg |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | |
|---|
| Tare range | -2500g |
|---|
| Minimum weight (USP) | 10g |
|---|
| Minimum weight (U=1%,k=2) | 1g |
|---|
| Power consumption | 500mA (wireless terminal - 1A) |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | 0,01g |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | yes |
|---|
PRODUCT DATASHEET
PS 3Y PRECISION BALANCES - PS 1500.3Y
| Readability [d] | 10mg |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 500mg |
|---|
| Repeatability (Max) | |
|---|
| Linearity | ±0,02g |
|---|
| Stabilization time | 1,5s |
|---|
| Sensitivity drift | 2ppm/°C in temperature +15 ÷ +35°C |
|---|
| Operating temperature | +10 ÷ +40°C |
|---|
| Weighing pan dimensions | 195×195mm |
|---|
| Power supply | 13,5 ÷ 16 V DC |
|---|
| Display | 5,7'' (panel touchscreen) |
|---|
| Communication interface | 2×USB, 2×RS 232, Ethernet, 4Inputs/4Outputs (digital), Wireless Connection |
|---|
| Packaging dimensions | 716×360×260mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | 5,3kg |
|---|
| Gross weight | 7,9kg |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | |
|---|
| Tare range | -1500g |
|---|
| Minimum weight (USP) | 10g |
|---|
| Minimum weight (U=1%,k=2) | 1g |
|---|
| Power consumption | 500mA (wireless terminal - 1A) |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | 0,01g |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | yes |
|---|
PRODUCT DATASHEET
PS 3Y PRECISION BALANCES - PS 1000.3Y
| Readability [d] | 0,001g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 20mg |
|---|
| Repeatability (Max) | 0,0015g |
|---|
| Linearity | ±0,003g |
|---|
| Stabilization time | 2s |
|---|
| Sensitivity drift | 2ppm/°C in temperature +15 ÷ +35°C |
|---|
| Operating temperature | +10 ÷ +40°C |
|---|
| Weighing pan dimensions | 128×128mm |
|---|
| Power supply | 13,5 ÷ 16 V DC |
|---|
| Display | 5,7'' (panel touchscreen) |
|---|
| Communication interface | 2×USB, 2×RS 232, Ethernet, 4Inputs/4Outputs (digital), Wireless Connection |
|---|
| Packaging dimensions | 716×360×260mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | 5,7kg |
|---|
| Gross weight | 8,3kg |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,0005g |
|---|
| Tare range | -1000g |
|---|
| Minimum weight (USP) | 1g |
|---|
| Minimum weight (U=1%,k=2) | 0,1g |
|---|
| Power consumption | 500mA (wireless terminal - 1A) |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | yes |
|---|
PRODUCT DATASHEET
PS 3Y PRECISION BALANCES - PS 750.3Y
| Readability [d] | 0,001g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 20mg |
|---|
| Repeatability (Max) | 0,0015g |
|---|
| Linearity | ±0,003g |
|---|
| Stabilization time | 2s |
|---|
| Sensitivity drift | 2ppm/°C in temperature +15 ÷ +35°C |
|---|
| Operating temperature | +10 ÷ +40°C |
|---|
| Weighing pan dimensions | 128×128mm |
|---|
| Power supply | 13,5 ÷ 16 V DC |
|---|
| Display | 5,7'' (panel touchscreen) |
|---|
| Communication interface | 2×USB, 2×RS 232, Ethernet, 4Inputs/4Outputs (digital), Wireless Connection |
|---|
| Packaging dimensions | 716×360×260mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | 5,7kg |
|---|
| Gross weight | 8,3kg |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,0005g |
|---|
| Tare range | -750g |
|---|
| Minimum weight (USP) | 1g |
|---|
| Minimum weight (U=1%,k=2) | 0,1g |
|---|
| Power consumption | 500mA (wireless terminal - 1A) |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | yes |
|---|
PRODUCT DATASHEET
PS 3Y PRECISION BALANCES - PS 600.3Y
| Readability [d] | 0,001g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 20mg |
|---|
| Repeatability (Max) | 0,0015g |
|---|
| Linearity | ±0,003g |
|---|
| Stabilization time | 2s |
|---|
| Sensitivity drift | 2ppm/°C in temperature +15 ÷ +35°C |
|---|
| Operating temperature | +10 ÷ +40°C |
|---|
| Weighing pan dimensions | 128×128mm |
|---|
| Power supply | 13,5 ÷ 16 V DC |
|---|
| Display | 5,7'' (panel touchscreen) |
|---|
| Communication interface | 2×USB, 2×RS 232, Ethernet, 4Inputs/4Outputs (digital), Wireless Connection |
|---|
| Packaging dimensions | 716×360×260mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | 5,7kg |
|---|
| Gross weight | 8,3kg |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,0005g |
|---|
| Tare range | -600g |
|---|
| Minimum weight (USP) | 1g |
|---|
| Minimum weight (U=1%,k=2) | 0,1g |
|---|
| Power consumption | 500mA (wireless terminal - 1A) |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | yes |
|---|
PRODUCT DATASHEET
PS 3Y PRECISION BALANCES - PS 450.3Y
| Readability [d] | 0,001g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 20mg |
|---|
| Repeatability (Max) | 0,001g |
|---|
| Linearity | ±0,002g |
|---|
| Stabilization time | 2s |
|---|
| Sensitivity drift | 2ppm/°C in temperature +15 ÷ +35°C |
|---|
| Operating temperature | +10 ÷ +40°C |
|---|
| Weighing pan dimensions | 128×128mm |
|---|
| Power supply | 13,5 ÷ 16 V DC |
|---|
| Display | 5,7'' (panel touchscreen) |
|---|
| Communication interface | 2×USB, 2×RS 232, Ethernet, 4Inputs/4Outputs (digital), Wireless Connection |
|---|
| Packaging dimensions | 716×360×260mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | 5,4kg |
|---|
| Gross weight | 7,9kg |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,0005g |
|---|
| Tare range | -450g |
|---|
| Minimum weight (USP) | 1g |
|---|
| Minimum weight (U=1%,k=2) | 0,1g |
|---|
| Power consumption | 500mA (wireless terminal - 1A) |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | yes |
|---|
PRODUCT DATASHEET
PS 3Y PRECISION BALANCES - PS 250.3Y
| Readability [d] | 0,001g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 20mg |
|---|
| Repeatability (Max) | 0,001g |
|---|
| Linearity | ±0,002g |
|---|
| Stabilization time | 2s |
|---|
| Sensitivity drift | 2ppm/°C in temperature +15 ÷ +35°C |
|---|
| Operating temperature | +10 ÷ +40°C |
|---|
| Weighing pan dimensions | 128×128mm |
|---|
| Power supply | 13,5 ÷ 16 V DC |
|---|
| Display | 5,7'' (panel touchscreen) |
|---|
| Communication interface | 2×USB, 2×RS 232, Ethernet, 4Inputs/4Outputs (digital), Wireless Connection |
|---|
| Packaging dimensions | 716×360×260mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | 5,3kg |
|---|
| Gross weight | 7,8kg |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,0005g |
|---|
| Tare range | -250g |
|---|
| Minimum weight (USP) | 1g |
|---|
| Minimum weight (U=1%,k=2) | 0,1g |
|---|
| Power consumption | 500mA (wireless terminal - 1A) |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | yes |
|---|
PRODUCT DATASHEET
PS 3Y PRECISION BALANCES - PS 200/2000.3Y
| Readability [d] | 0,001/0,01g |
|---|
| Maximum capacity [Max] | |
|---|
| Minimum load | 20mg |
|---|
| Repeatability (Max) | 0,001/0,01g |
|---|
| Linearity | ±0,002/0,01g |
|---|
| Stabilization time | 2/1,5s |
|---|
| Sensitivity drift | 2ppm/°C in temperature +15 ÷ +35°C |
|---|
| Operating temperature | +10 ÷ +40°C |
|---|
| Weighing pan dimensions | 128×128mm |
|---|
| Power supply | 13,5 ÷ 16 V DC |
|---|
| Display | 5,7'' (panel touchscreen) |
|---|
| Communication interface | 2×USB, 2×RS 232, Ethernet, 4Inputs/4Outputs (digital), Wireless Connection |
|---|
| Packaging dimensions | 716×360×260mm |
|---|
| Adjustment | internal (automatic) |
|---|
| Net weight | 5,7kg |
|---|
| Gross weight | 8,3kg |
|---|
| Database capacity | |
|---|
| Atmospheric humidity | |
|---|
| Repeatability (5% Max) | 0,0005/0,005g |
|---|
| Tare range | -200/2000g |
|---|
| Minimum weight (USP) | 1g |
|---|
| Minimum weight (U=1%,k=2) | 0,1g |
|---|
| Power consumption | 500mA (wireless terminal - 1A) |
|---|
| Touch-free operation | |
|---|
| Device dimensions | |
|---|
| Net weight/gross weight | |
|---|
| OIML Class | |
|---|
| Operation time on batteries | |
|---|
| Preload range | |
|---|
| Protection class | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Storage temperature | |
|---|
| Verification scale interval | |
|---|
| Weight | |
|---|
| Verification | yes |
|---|