PRODUCT DATASHEET
Please, use model selector above to see product datasheet.
PRODUCT DATASHEET
MWMH MODULES - MWMH 100 ELECTROMAGNETIC COMPENSATION WEIGHING MODULE
Maximum capacity [Max] | |
---|
Minimum load | |
---|
Readability [d] | 0,05g |
---|
Tare range | -1000g |
---|
Repeatability (5% Max) | |
---|
Repeatability (Max) | |
---|
Linearity | |
---|
Stabilization time | 0,1s |
---|
Sensitivity drift | |
---|
Operating temperature | +5 ÷ +40°C |
---|
Weighing pan dimensions | 212×174mm |
---|
Power supply | 12 ÷ 24 V DC |
---|
Display | |
---|
Communication interface | |
---|
Packaging dimensions | |
---|
Adjustment | external |
---|
Net weight | |
---|
Gross weight | |
---|
Atmospheric humidity | 40% ÷ 80% |
---|
Minimum weight (USP) | |
---|
Minimum weight (U=1%,k=2) | |
---|
Eccentric load deviation | |
---|
Sensitivity offset | |
---|
Sensitivity time drift | |
---|
Power consumption | |
---|
4I/4O module | |
---|
Add weighing platform module | |
---|
Connection of load cells | |
---|
Device dimensions | |
---|
Housing | |
---|
Inputs/Outputs (option) | |
---|
Load cell excitation voltage | |
---|
Max number of platforms | |
---|
Maximum increase of signal | |
---|
Maximum load cell impedance | |
---|
Max qty of divisions conv | |
---|
Max qty of verific units | |
---|
Memory | |
---|
Minimum load cell impedance | |
---|
Min voltage/verification unit | |
---|
Multiple range | |
---|
OIML Class | |
---|
Preload range | |
---|
Processor | |
---|
Profibus module (option) | |
---|
Protection class | IP 65 or IP 69K |
---|
Repeatability | |
---|
RS 232, RS 485 transm speed | |
---|
Sensitivity tempr drift | |
---|
Verification scale interval | 0,1g |
---|
PRODUCT DATASHEET
MWMH MODULES - MWMH 200 ELECTROMAGNETIC COMPENSATION WEIGHING MODULE
Maximum capacity [Max] | |
---|
Minimum load | |
---|
Readability [d] | 0,02g |
---|
Tare range | -2000g |
---|
Repeatability (5% Max) | |
---|
Repeatability (Max) | |
---|
Linearity | |
---|
Stabilization time | <0,1s |
---|
Sensitivity drift | |
---|
Operating temperature | +5 ÷ +40°C |
---|
Weighing pan dimensions | 212×174mm |
---|
Power supply | 12 ÷ 24 V DC |
---|
Display | |
---|
Communication interface | |
---|
Packaging dimensions | |
---|
Adjustment | external |
---|
Net weight | |
---|
Gross weight | |
---|
Atmospheric humidity | 40% ÷ 80% |
---|
Minimum weight (USP) | |
---|
Minimum weight (U=1%,k=2) | |
---|
Eccentric load deviation | |
---|
Sensitivity offset | |
---|
Sensitivity time drift | |
---|
Power consumption | |
---|
4I/4O module | |
---|
Add weighing platform module | |
---|
Connection of load cells | |
---|
Device dimensions | |
---|
Housing | |
---|
Inputs/Outputs (option) | |
---|
Load cell excitation voltage | |
---|
Max number of platforms | |
---|
Maximum increase of signal | |
---|
Maximum load cell impedance | |
---|
Max qty of divisions conv | |
---|
Max qty of verific units | |
---|
Memory | |
---|
Minimum load cell impedance | |
---|
Min voltage/verification unit | |
---|
Multiple range | |
---|
OIML Class | |
---|
Preload range | 10kg |
---|
Processor | |
---|
Profibus module (option) | |
---|
Protection class | IP 65 or IP 69K |
---|
Repeatability | |
---|
RS 232, RS 485 transm speed | |
---|
Sensitivity tempr drift | |
---|
Verification scale interval | 0,2g |
---|
PRODUCT DATASHEET
MWMH MODULES - MWMH 500 ELECTROMAGNETIC COMPENSATION WEIGHING MODULE
Maximum capacity [Max] | |
---|
Minimum load | |
---|
Readability [d] | 0,5g |
---|
Tare range | -5000g |
---|
Repeatability (5% Max) | |
---|
Repeatability (Max) | |
---|
Linearity | |
---|
Stabilization time | <0,1s |
---|
Sensitivity drift | |
---|
Operating temperature | +5 ÷ +40°C |
---|
Weighing pan dimensions | 212×174mm |
---|
Power supply | 12 ÷ 24 V DC |
---|
Display | |
---|
Communication interface | |
---|
Packaging dimensions | |
---|
Adjustment | external |
---|
Net weight | |
---|
Gross weight | |
---|
Atmospheric humidity | 40% ÷ 80% |
---|
Minimum weight (USP) | |
---|
Minimum weight (U=1%,k=2) | |
---|
Eccentric load deviation | |
---|
Sensitivity offset | |
---|
Sensitivity time drift | |
---|
Power consumption | |
---|
4I/4O module | |
---|
Add weighing platform module | |
---|
Connection of load cells | |
---|
Device dimensions | |
---|
Housing | |
---|
Inputs/Outputs (option) | |
---|
Load cell excitation voltage | |
---|
Max number of platforms | |
---|
Maximum increase of signal | |
---|
Maximum load cell impedance | |
---|
Max qty of divisions conv | |
---|
Max qty of verific units | |
---|
Memory | |
---|
Minimum load cell impedance | |
---|
Min voltage/verification unit | |
---|
Multiple range | |
---|
OIML Class | |
---|
Preload range | 15kg |
---|
Processor | |
---|
Profibus module (option) | |
---|
Protection class | IP 65 or IP 69K |
---|
Repeatability | |
---|
RS 232, RS 485 transm speed | |
---|
Sensitivity tempr drift | |
---|
Verification scale interval | 0,5g |
---|
PRODUCT DATASHEET
MWMH MODULES - MWMH 1000 ELECTROMAGNETIC COMPENSATION WEIGHING MODULE
Maximum capacity [Max] | |
---|
Minimum load | |
---|
Readability [d] | 0,5g |
---|
Tare range | -10000g |
---|
Repeatability (5% Max) | |
---|
Repeatability (Max) | |
---|
Linearity | |
---|
Stabilization time | <0,1s |
---|
Sensitivity drift | |
---|
Operating temperature | +5 ÷ +40°C |
---|
Weighing pan dimensions | 212×174mm |
---|
Power supply | 12 ÷ 24 V DC |
---|
Display | |
---|
Communication interface | |
---|
Packaging dimensions | |
---|
Adjustment | external |
---|
Net weight | |
---|
Gross weight | |
---|
Atmospheric humidity | 40% ÷ 80% |
---|
Minimum weight (USP) | |
---|
Minimum weight (U=1%,k=2) | |
---|
Eccentric load deviation | |
---|
Sensitivity offset | |
---|
Sensitivity time drift | |
---|
Power consumption | |
---|
4I/4O module | |
---|
Add weighing platform module | |
---|
Connection of load cells | |
---|
Device dimensions | |
---|
Housing | |
---|
Inputs/Outputs (option) | |
---|
Load cell excitation voltage | |
---|
Max number of platforms | |
---|
Maximum increase of signal | |
---|
Maximum load cell impedance | |
---|
Max qty of divisions conv | |
---|
Max qty of verific units | |
---|
Memory | |
---|
Minimum load cell impedance | |
---|
Min voltage/verification unit | |
---|
Multiple range | |
---|
OIML Class | |
---|
Preload range | 15kg |
---|
Processor | |
---|
Profibus module (option) | |
---|
Protection class | IP 65 or IP 69K |
---|
Repeatability | |
---|
RS 232, RS 485 transm speed | |
---|
Sensitivity tempr drift | |
---|
Verification scale interval | 1g |
---|