PRODUCT DATASHEET
Please, use model selector above to see product datasheet.
PRODUCT DATASHEET
AS R ANALYTICAL BALANCES - AS 310.R2
| Maximum capacity [Max] | |
|---|
| Minimum load | 10mg |
|---|
| Readability [d] | 0,1mg |
|---|
| Power supply | 12 ÷ 16 V DC |
|---|
| Adjustment | internal (automatic) |
|---|
| Atmospheric humidity | |
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Wireless Connection (option) |
|---|
| Database capacity | |
|---|
| Display | LCD (backlit) |
|---|
| Gross weight | 7,3kg |
|---|
| Linearity | ±0,3mg |
|---|
| Net weight | 5,3kg |
|---|
| Operating temperature | +10 ° - +40 °C |
|---|
| Packaging dimensions | 495×400×515mm |
|---|
| Repeatability (5% Max) | 0,08mg |
|---|
| Repeatability (Max) | 0,15mg |
|---|
| Sensitivity drift | 1 ppm/°C in temperature +10 ° - +40 °C |
|---|
| Stabilization time | 2s |
|---|
| Tare range | -310g |
|---|
| Weighing pan dimensions | ? 100mm |
|---|
| Minimum weight (USP) | 160mg |
|---|
| Minimum weight (U=1%,k=2) | 16mg |
|---|
| Eccentric load deviation | |
|---|
| Sensitivity offset | |
|---|
| Sensitivity time drift | |
|---|
| Weighing chamber dimensions | |
|---|
| Power consumption | |
|---|
| Touch-free operation | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Weight | |
|---|
PRODUCT DATASHEET
AS R ANALYTICAL BALANCES - AS 220.R2
| Maximum capacity [Max] | |
|---|
| Minimum load | 10mg |
|---|
| Readability [d] | 0,1mg |
|---|
| Power supply | 12 ÷ 16 V DC |
|---|
| Adjustment | internal (automatic) |
|---|
| Atmospheric humidity | |
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Wireless Connection (option) |
|---|
| Database capacity | |
|---|
| Display | LCD (backlit) |
|---|
| Gross weight | 7,3kg |
|---|
| Linearity | ±0,2mg |
|---|
| Net weight | 5,3kg |
|---|
| Operating temperature | +10 ° - +40 °C |
|---|
| Packaging dimensions | 495×400×515mm |
|---|
| Repeatability (5% Max) | 0,08mg |
|---|
| Repeatability (Max) | 0,1mg |
|---|
| Sensitivity drift | 1 ppm/°C in temperature +10 ° - +40 °C |
|---|
| Stabilization time | 2s |
|---|
| Tare range | -220g |
|---|
| Weighing pan dimensions | ø 100mm |
|---|
| Minimum weight (USP) | 160mg |
|---|
| Minimum weight (U=1%,k=2) | 16mg |
|---|
| Eccentric load deviation | |
|---|
| Sensitivity offset | |
|---|
| Sensitivity time drift | |
|---|
| Weighing chamber dimensions | |
|---|
| Power consumption | |
|---|
| Touch-free operation | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Weight | |
|---|
PRODUCT DATASHEET
AS R ANALYTICAL BALANCES - AS 160.R2
| Maximum capacity [Max] | |
|---|
| Minimum load | 10mg |
|---|
| Readability [d] | 0,1mg |
|---|
| Power supply | 12 ÷ 16 V DC |
|---|
| Adjustment | internal (automatic) |
|---|
| Atmospheric humidity | |
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Wireless Connection (option) |
|---|
| Database capacity | |
|---|
| Display | LCD (backlit) |
|---|
| Gross weight | 7,3kg |
|---|
| Linearity | ±0,2mg |
|---|
| Net weight | 5,3kg |
|---|
| Operating temperature | +10 ° - +40 °C |
|---|
| Packaging dimensions | 495×400×515mm |
|---|
| Repeatability (5% Max) | 0,08mg |
|---|
| Repeatability (Max) | 0,1mg |
|---|
| Sensitivity drift | 1 ppm/°C in temperature +10 ° - +40 °C |
|---|
| Stabilization time | 2s |
|---|
| Tare range | -160g |
|---|
| Weighing pan dimensions | ø 100mm |
|---|
| Minimum weight (USP) | 160mg |
|---|
| Minimum weight (U=1%,k=2) | 16mg |
|---|
| Eccentric load deviation | |
|---|
| Sensitivity offset | |
|---|
| Sensitivity time drift | |
|---|
| Weighing chamber dimensions | |
|---|
| Power consumption | |
|---|
| Touch-free operation | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Weight | |
|---|
PRODUCT DATASHEET
AS R ANALYTICAL BALANCES - AS 110.R2
| Maximum capacity [Max] | |
|---|
| Minimum load | 10mg |
|---|
| Readability [d] | 0,1mg |
|---|
| Power supply | 12 ÷ 16 V DC |
|---|
| Adjustment | internal (automatic) |
|---|
| Atmospheric humidity | |
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Wireless Connection (option) |
|---|
| Database capacity | |
|---|
| Display | LCD (backlit) |
|---|
| Gross weight | 7,3kg |
|---|
| Linearity | ±0,2mg |
|---|
| Net weight | 5,3kg |
|---|
| Operating temperature | +10 ° - +40 °C |
|---|
| Packaging dimensions | 495×400×515mm |
|---|
| Repeatability (5% Max) | 0,08mg |
|---|
| Repeatability (Max) | 0,1mg |
|---|
| Sensitivity drift | 1 ppm/°C in temperature +10 ° - +40 °C |
|---|
| Stabilization time | 2s |
|---|
| Tare range | -110g |
|---|
| Weighing pan dimensions | ø 100mm |
|---|
| Minimum weight (USP) | 160mg |
|---|
| Minimum weight (U=1%,k=2) | 16mg |
|---|
| Eccentric load deviation | |
|---|
| Sensitivity offset | |
|---|
| Sensitivity time drift | |
|---|
| Weighing chamber dimensions | |
|---|
| Power consumption | |
|---|
| Touch-free operation | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Weight | |
|---|
PRODUCT DATASHEET
AS R ANALYTICAL BALANCES - AS 82/220.R2
| Maximum capacity [Max] | |
|---|
| Minimum load | 1mg |
|---|
| Readability [d] | 0,01/0,1mg |
|---|
| Power supply | 12 ÷ 16 V DC |
|---|
| Adjustment | internal (automatic) |
|---|
| Atmospheric humidity | |
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Wireless Connection (option) |
|---|
| Database capacity | |
|---|
| Display | LCD (backlit) |
|---|
| Gross weight | 7,3kg |
|---|
| Linearity | ±0,06mg |
|---|
| Net weight | 5,3kg |
|---|
| Operating temperature | +10 ° - +40 °C |
|---|
| Packaging dimensions | 495×400×515mm |
|---|
| Repeatability (5% Max) | 0,015mg |
|---|
| Repeatability (Max) | 0,1mg |
|---|
| Sensitivity drift | 1 ppm/°C in temperature +10 ° - +40 °C |
|---|
| Stabilization time | 2s |
|---|
| Tare range | -220g |
|---|
| Weighing pan dimensions | ø 90 + ø 85 (option)mm |
|---|
| Minimum weight (USP) | 30mg |
|---|
| Minimum weight (U=1%,k=2) | 3mg |
|---|
| Eccentric load deviation | |
|---|
| Sensitivity offset | |
|---|
| Sensitivity time drift | |
|---|
| Weighing chamber dimensions | |
|---|
| Power consumption | |
|---|
| Touch-free operation | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Weight | |
|---|
PRODUCT DATASHEET
AS R ANALYTICAL BALANCES - AS 62.R2
| Maximum capacity [Max] | |
|---|
| Minimum load | 1mg |
|---|
| Readability [d] | 0,01mg |
|---|
| Power supply | 12 ÷ 16 V DC |
|---|
| Adjustment | internal (automatic) |
|---|
| Atmospheric humidity | |
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Wireless Connection (option) |
|---|
| Database capacity | |
|---|
| Display | LCD (backlit) |
|---|
| Gross weight | 7,3kg |
|---|
| Linearity | ±0,06mg |
|---|
| Net weight | 5,3kg |
|---|
| Operating temperature | +10 ° - +40 °C |
|---|
| Packaging dimensions | 495×400×515mm |
|---|
| Repeatability (5% Max) | 0,015mg |
|---|
| Repeatability (Max) | 0,03mg |
|---|
| Sensitivity drift | 1 ppm/°C in temperature +10 ° - +40 °C |
|---|
| Stabilization time | 2s |
|---|
| Tare range | -62g |
|---|
| Weighing pan dimensions | ø 90 + ø 85 (option)mm |
|---|
| Minimum weight (USP) | 30mg |
|---|
| Minimum weight (U=1%,k=2) | 3mg |
|---|
| Eccentric load deviation | |
|---|
| Sensitivity offset | |
|---|
| Sensitivity time drift | |
|---|
| Weighing chamber dimensions | |
|---|
| Power consumption | |
|---|
| Touch-free operation | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Weight | |
|---|
PRODUCT DATASHEET
AS R ANALYTICAL BALANCES - AS 60/220.R2
| Maximum capacity [Max] | |
|---|
| Minimum load | 1mg |
|---|
| Readability [d] | 0,01/0,1mg |
|---|
| Power supply | 12 ÷ 16 V DC |
|---|
| Adjustment | internal (automatic) |
|---|
| Atmospheric humidity | |
|---|
| Communication interface | 2×RS 232, USB-A, USB-B, Wireless Connection (option) |
|---|
| Database capacity | |
|---|
| Display | LCD (backlit) |
|---|
| Gross weight | 7,3kg |
|---|
| Linearity | ±0,06mg |
|---|
| Net weight | 5,3kg |
|---|
| Operating temperature | +10 ° - +40 °C |
|---|
| Packaging dimensions | 495×400×515mm |
|---|
| Repeatability (5% Max) | 0,015mg |
|---|
| Repeatability (Max) | 0,1mg |
|---|
| Sensitivity drift | 1 ppm/°C in temperature +10 ° - +40 °C |
|---|
| Stabilization time | 2s |
|---|
| Tare range | -220g |
|---|
| Weighing pan dimensions | ø 90 + ø 85 (option)mm |
|---|
| Minimum weight (USP) | 160 |
|---|
| Minimum weight (U=1%,k=2) | 16 |
|---|
| Eccentric load deviation | |
|---|
| Sensitivity offset | |
|---|
| Sensitivity time drift | |
|---|
| Weighing chamber dimensions | |
|---|
| Power consumption | |
|---|
| Touch-free operation | |
|---|
| Repeatability | |
|---|
| Sensitivity tempr drift | |
|---|
| Weight | |
|---|