{"id":1224,"date":"2018-12-21T11:42:25","date_gmt":"2018-12-21T10:42:25","guid":{"rendered":"https:\/\/radwag-merleg.hu\/?post_type=product&#038;p=1224"},"modified":"2024-02-15T18:17:46","modified_gmt":"2024-02-15T17:17:46","slug":"rmcs-system","status":"publish","type":"product","link":"https:\/\/radwag-merleg.hu\/hu\/product\/rmcs-system\/","title":{"rendered":"RMCS SYSTEM"},"content":{"rendered":"<p>RMCS system is a proprietary RADWAG software intended for support of calibration and testing procedures in a laboratory, from the moment of accepting an order, through its progress to calibration certificate issuing. The software manages the complete calibration and testing process.<\/p>\n<p> Mass comparators and software for network management of calibration process provide improved efficiency, reliable measurement results and complete calibration process documentation, plus lower labour costs.<br \/> The system enables to initiate the calibration procedure by means of a task order sent to a mass comparator, and autonomously by the mass comparator itself. In both cases, the data is transferred to the software for the purpose of registering, controlling and finally issuing a calibration certificate.<br \/> Mass comparators linked in the RMCS system autonomously communicate with THB modules recording ambient conditions (temperature, humidity, atmospheric pressure) throughout the whole control process. The modules are detachable from the mass comparators, this makes calibration of their sensors easy.<br \/> Data on current ambient conditions is displayed in real time on mass comparator&rsquo;s display. The data is also sent do RMCS software for control and archiving purposes.<\/p>\n<p> <strong>System modules<\/strong><br \/> <strong>Ambient conditions monitoring module<\/strong> <\/p>\n<ul>\n<li> \t\tInstalled, direct communicates with the mass comparator;<\/li>\n<li> \t\tRecord of ambient conditions (temperature, humidity, atmospheric pressure) and air density calculation;<\/li>\n<li> \t\tConstant monitoring of ambient conditions in direct vicinity of the mass comparator and its weighing chamber;<\/li>\n<li> \t\tGraphic presentation of ambient conditions on mass comparator&rsquo;s display.<\/li>\n<\/ul>\n<p> <strong>Weighing module<\/strong> <\/p>\n<ul>\n<li> \t\tAutomatic and\/or manual mass comparators as components of the RMCS system;<\/li>\n<li> \t\tAccess to reference weights and test weights databases via RMCS software;<\/li>\n<li> \t\tPerformance of calibration tasks ordered via the RMCS software;<\/li>\n<li> \t\tSelf-test procedure determining mass comparator&rsquo;s repeatability parameter;<\/li>\n<li> \t\tTransfer of measurement results to the software memory.<\/li>\n<\/ul>\n<p> <strong>Calculating and data storage module<\/strong> <\/p>\n<ul>\n<li> \t\tSending tasks to mass comparators;<\/li>\n<li> \t\tDownloading mass and ambient conditions data from mass comparators;<\/li>\n<li> \t\tOperation on client databases \/ tasks \/ standards;<\/li>\n<li> \t\tMonitoring of calibration dates;<\/li>\n<li> \t\tDatabase of completed calibrations, documentation printing and archiving.<\/li>\n<\/ul>\n<p> <strong>Functions<\/strong> <\/p>\n<ul>\n<li> \t\tComplete management of a metrology laboratory calibrating mass standards and weights using RADWAG mass comparators of Y series;<\/li>\n<li> \t\tCalibration using ABBA and ABA methods;<\/li>\n<li> \t\tNetwork supervision over many PC workstations thanks to use of MS SQL database;<\/li>\n<li> \t\tComplete management of calibration orders;<\/li>\n<li> \t\tExtended database of reference weights and test weights;<\/li>\n<li> \t\tExtended database of clients, operators and users;<\/li>\n<li> \t\tDatabase of manual and automatic mass comparators;<\/li>\n<li> \t\tDatabase of calibration orders;<\/li>\n<li> \t\tManagement of pending tasks based on issued calibration orders;<\/li>\n<li> \t\tTasks and orders schedule;<\/li>\n<li> \t\tNot ordered weight test &ndash; quick check;<\/li>\n<li> \t\tManual or automatic calibration of weights;<\/li>\n<li> \t\tCommunication with automatic RADWAG mass comparators;<\/li>\n<li> \t\tBilateral data synchronization with RADWAG mass comparators;<\/li>\n<li> \t\tCalibration process reports;<\/li>\n<li> \t\tIssuing calibration certificates according to pre-defined template;<\/li>\n<li> \t\tExport of report results to various file formats: PDF, MS Word, Excel;<\/li>\n<li> \t\tRecord of events;<\/li>\n<li> \t\tRegister of orders and calibration certificates;<\/li>\n<li> \t\tArchive files of calibration protocols, orders, calibration certificates and ambient conditions;<\/li>\n<li> \t\tSecured access to the software &ndash; log in procedure using password.<\/li>\n<\/ul>\n<p> \t&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>RMCS system is a proprietary RADWAG software intended for support of calibration and testing procedures in a laboratory, from the moment of accepting an order, through its progress to calibration certificate issuing. The software manages the complete calibration and testing process. Mass comparators and software for network management of calibration process provide improved efficiency, reliable<br \/><a class=\"more-link\" href=\"https:\/\/radwag-merleg.hu\/hu\/product\/rmcs-system\/\"><br \/>\n        Read More<span class=\"screen-reader-text\"> &#8220;RMCS SYSTEM&#8221;<\/span><\/a><\/p>\n","protected":false},"featured_media":1226,"template":"","meta":{"ngg_post_thumbnail":0},"gallery_images":[1226],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.6.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>RMCS SYSTEM - Radwag m\u00e9rlegek<\/title>\n<meta name=\"description\" content=\"RMCS system is a proprietary RADWAG software intended for support of calibration and testing procedures in a laboratory, from the moment of accepting an order, through its progress to calibration certificate issuing. The software manages the complete calibration and testing process. Mass comparators and software for network management of calibration process provide improved efficiency, reliable measurement results and complete calibration process documentation, plus lower labour costs. The system enables to initiate the calibration procedure by means of a task order sent to a mass comparator, and autonomously by the mass comparator itself. In both cases, the data is transferred to the software for the purpose of registering, controlling and finally issuing a calibration certificate. Mass comparators linked in the RMCS system autonomously communicate with THB modules recording ambient conditions (temperature, humidity, atmospheric pressure) throughout the whole control process. The modules are detachable from the mass comparators, this makes calibration of their sensors easy. Data on current ambient conditions is displayed in real time on mass comparator&rsquo;s display. The data is also sent do RMCS software for control and archiving purposes. System modules Ambient conditions monitoring module   Installed, direct communicates with the mass comparator;   Record of ambient conditions (temperature, humidity, atmospheric pressure) and air density calculation;   Constant monitoring of ambient conditions in direct vicinity of the mass comparator and its weighing chamber;   Graphic presentation of ambient conditions on mass comparator&rsquo;s display. Weighing module   Automatic and\/or manual mass comparators as components of the RMCS system;   Access to reference weights and test weights databases via RMCS software;   Performance of calibration tasks ordered via the RMCS software;   Self-test procedure determining mass comparator&rsquo;s repeatability parameter;   Transfer of measurement results to the software memory. Calculating and data storage module   Sending tasks to mass comparators;   Downloading mass and ambient conditions data from mass comparators;   Operation on client databases \/ tasks \/ standards;   Monitoring of calibration dates;   Database of completed calibrations, documentation printing and archiving. Functions   Complete management of a metrology laboratory calibrating mass standards and weights using RADWAG mass comparators of Y series;   Calibration using ABBA and ABA methods;   Network supervision over many PC workstations thanks to use of MS SQL database;   Complete management of calibration orders;   Extended database of reference weights and test weights;   Extended database of clients, operators and users;   Database of manual and automatic mass comparators;   Database of calibration orders;   Management of pending tasks based on issued calibration orders;   Tasks and orders schedule;   Not ordered weight test &ndash; quick check;   Manual or automatic calibration of weights;   Communication with automatic RADWAG mass comparators;   Bilateral data synchronization with RADWAG mass comparators;   Calibration process reports;   Issuing calibration certificates according to pre-defined template;   Export of report results to various file formats: PDF, MS Word, Excel;   Record of events;   Register of orders and calibration certificates;   Archive files of calibration protocols, orders, calibration certificates and ambient conditions;   Secured access to the software &ndash; log in procedure using password.  &nbsp;\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/radwag-merleg.hu\/hu\/product\/rmcs-system\/\" \/>\n<meta property=\"og:locale\" content=\"hu_HU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"RMCS SYSTEM - Radwag m\u00e9rlegek\" \/>\n<meta property=\"og:description\" content=\"RMCS system is a proprietary RADWAG software intended for support of calibration and testing procedures in a laboratory, from the moment of accepting an order, through its progress to calibration certificate issuing. The software manages the complete calibration and testing process. Mass comparators and software for network management of calibration process provide improved efficiency, reliable measurement results and complete calibration process documentation, plus lower labour costs. The system enables to initiate the calibration procedure by means of a task order sent to a mass comparator, and autonomously by the mass comparator itself. In both cases, the data is transferred to the software for the purpose of registering, controlling and finally issuing a calibration certificate. Mass comparators linked in the RMCS system autonomously communicate with THB modules recording ambient conditions (temperature, humidity, atmospheric pressure) throughout the whole control process. The modules are detachable from the mass comparators, this makes calibration of their sensors easy. Data on current ambient conditions is displayed in real time on mass comparator&rsquo;s display. The data is also sent do RMCS software for control and archiving purposes. System modules Ambient conditions monitoring module   Installed, direct communicates with the mass comparator;   Record of ambient conditions (temperature, humidity, atmospheric pressure) and air density calculation;   Constant monitoring of ambient conditions in direct vicinity of the mass comparator and its weighing chamber;   Graphic presentation of ambient conditions on mass comparator&rsquo;s display. Weighing module   Automatic and\/or manual mass comparators as components of the RMCS system;   Access to reference weights and test weights databases via RMCS software;   Performance of calibration tasks ordered via the RMCS software;   Self-test procedure determining mass comparator&rsquo;s repeatability parameter;   Transfer of measurement results to the software memory. Calculating and data storage module   Sending tasks to mass comparators;   Downloading mass and ambient conditions data from mass comparators;   Operation on client databases \/ tasks \/ standards;   Monitoring of calibration dates;   Database of completed calibrations, documentation printing and archiving. Functions   Complete management of a metrology laboratory calibrating mass standards and weights using RADWAG mass comparators of Y series;   Calibration using ABBA and ABA methods;   Network supervision over many PC workstations thanks to use of MS SQL database;   Complete management of calibration orders;   Extended database of reference weights and test weights;   Extended database of clients, operators and users;   Database of manual and automatic mass comparators;   Database of calibration orders;   Management of pending tasks based on issued calibration orders;   Tasks and orders schedule;   Not ordered weight test &ndash; quick check;   Manual or automatic calibration of weights;   Communication with automatic RADWAG mass comparators;   Bilateral data synchronization with RADWAG mass comparators;   Calibration process reports;   Issuing calibration certificates according to pre-defined template;   Export of report results to various file formats: PDF, MS Word, Excel;   Record of events;   Register of orders and calibration certificates;   Archive files of calibration protocols, orders, calibration certificates and ambient conditions;   Secured access to the software &ndash; log in procedure using password.  &nbsp;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/radwag-merleg.hu\/hu\/product\/rmcs-system\/\" \/>\n<meta property=\"og:site_name\" content=\"Radwag m\u00e9rlegek\" \/>\n<meta property=\"article:modified_time\" content=\"2024-02-15T17:17:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/radwag-merleg.hu\/wp-content\/uploads\/sites\/3\/2018\/12\/emalog_radwag_software_szoftver_rmcs_box.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"799\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c1r\">\n\t<meta name=\"twitter:data1\" content=\"\">\n\t<meta name=\"twitter:label2\" content=\"Availability\">\n\t<meta name=\"twitter:data2\" content=\"Out of stock\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/radwag-merleg.hu\/hu\/#organization\",\"name\":\"EMALOG Kft.\",\"url\":\"https:\/\/radwag-merleg.hu\/hu\/\",\"sameAs\":[],\"logo\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/radwag-merleg.hu\/hu\/#logo\",\"inLanguage\":\"hu\",\"url\":\"https:\/\/radwag-merleg.hu\/wp-content\/uploads\/sites\/3\/2024\/02\/emalog-yellow.png\",\"width\":600,\"height\":600,\"caption\":\"EMALOG Kft.\"},\"image\":{\"@id\":\"https:\/\/radwag-merleg.hu\/hu\/#logo\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/radwag-merleg.hu\/hu\/#website\",\"url\":\"https:\/\/radwag-merleg.hu\/hu\/\",\"name\":\"Radwag m\\u00e9rlegek\",\"description\":\"prec\\u00edzi\\u00f3s \\u00e9s analitikai m\\u00e9rlegek az EMALOG Kft. k\\u00edn\\u00e1lat\\u00e1ban\",\"publisher\":{\"@id\":\"https:\/\/radwag-merleg.hu\/hu\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/radwag-merleg.hu\/hu\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"hu\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/radwag-merleg.hu\/hu\/product\/rmcs-system\/#primaryimage\",\"inLanguage\":\"hu\",\"url\":\"https:\/\/radwag-merleg.hu\/wp-content\/uploads\/sites\/3\/2018\/12\/emalog_radwag_software_szoftver_rmcs_box.jpg\",\"width\":800,\"height\":799},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/radwag-merleg.hu\/hu\/product\/rmcs-system\/#webpage\",\"url\":\"https:\/\/radwag-merleg.hu\/hu\/product\/rmcs-system\/\",\"name\":\"RMCS SYSTEM - Radwag m\\u00e9rlegek\",\"isPartOf\":{\"@id\":\"https:\/\/radwag-merleg.hu\/hu\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/radwag-merleg.hu\/hu\/product\/rmcs-system\/#primaryimage\"},\"datePublished\":\"2018-12-21T10:42:25+00:00\",\"dateModified\":\"2024-02-15T17:17:46+00:00\",\"description\":\"RMCS system is a proprietary RADWAG software intended for support of calibration and testing procedures in a laboratory, from the moment of accepting an order, through its progress to calibration certificate issuing. The software manages the complete calibration and testing process. Mass comparators and software for network management of calibration process provide improved efficiency, reliable measurement results and complete calibration process documentation, plus lower labour costs. The system enables to initiate the calibration procedure by means of a task order sent to a mass comparator, and autonomously by the mass comparator itself. In both cases, the data is transferred to the software for the purpose of registering, controlling and finally issuing a calibration certificate. Mass comparators linked in the RMCS system autonomously communicate with THB modules recording ambient conditions (temperature, humidity, atmospheric pressure) throughout the whole control process. The modules are detachable from the mass comparators, this makes calibration of their sensors easy. Data on current ambient conditions is displayed in real time on mass comparator&rsquo;s display. The data is also sent do RMCS software for control and archiving purposes. System modules Ambient conditions monitoring module Installed, direct communicates with the mass comparator; Record of ambient conditions (temperature, humidity, atmospheric pressure) and air density calculation; Constant monitoring of ambient conditions in direct vicinity of the mass comparator and its weighing chamber; Graphic presentation of ambient conditions on mass comparator&rsquo;s display. Weighing module Automatic and\/or manual mass comparators as components of the RMCS system; Access to reference weights and test weights databases via RMCS software; Performance of calibration tasks ordered via the RMCS software; Self-test procedure determining mass comparator&rsquo;s repeatability parameter; Transfer of measurement results to the software memory. Calculating and data storage module Sending tasks to mass comparators; Downloading mass and ambient conditions data from mass comparators; Operation on client databases \/ tasks \/ standards; Monitoring of calibration dates; Database of completed calibrations, documentation printing and archiving. Functions Complete management of a metrology laboratory calibrating mass standards and weights using RADWAG mass comparators of Y series; Calibration using ABBA and ABA methods; Network supervision over many PC workstations thanks to use of MS SQL database; Complete management of calibration orders; Extended database of reference weights and test weights; Extended database of clients, operators and users; Database of manual and automatic mass comparators; Database of calibration orders; Management of pending tasks based on issued calibration orders; Tasks and orders schedule; Not ordered weight test &ndash; quick check; Manual or automatic calibration of weights; Communication with automatic RADWAG mass comparators; Bilateral data synchronization with RADWAG mass comparators; Calibration process reports; Issuing calibration certificates according to pre-defined template; Export of report results to various file formats: PDF, MS Word, Excel; Record of events; Register of orders and calibration certificates; Archive files of calibration protocols, orders, calibration certificates and ambient conditions; Secured access to the software &ndash; log in procedure using password. &nbsp;\",\"inLanguage\":\"hu\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/radwag-merleg.hu\/hu\/product\/rmcs-system\/\"]}]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/radwag-merleg.hu\/hu\/wp-json\/wp\/v2\/product\/1224"}],"collection":[{"href":"https:\/\/radwag-merleg.hu\/hu\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/radwag-merleg.hu\/hu\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/radwag-merleg.hu\/hu\/wp-json\/wp\/v2\/media\/1226"}],"wp:attachment":[{"href":"https:\/\/radwag-merleg.hu\/hu\/wp-json\/wp\/v2\/media?parent=1224"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}