{"version":"1.0","provider_name":"Radwag m\u00e9rlegek","provider_url":"https:\/\/radwag-merleg.hu\/hu\/","author_name":"Vogel Krist\u00f3f Istv\u00e1n","author_url":"https:\/\/radwag-merleg.hu\/hu\/author\/kristof\/","title":"WORKSTATION FOR PIPETTES CALIBRATION - Radwag m\u00e9rlegek","type":"rich","width":600,"height":338,"html":"<blockquote class=\"wp-embedded-content\" data-secret=\"rtv0TYsDZD\"><a href=\"https:\/\/radwag-merleg.hu\/hu\/product\/workstation-for-pipettes-calibration\/\">WORKSTATION FOR PIPETTES CALIBRATION<\/a><\/blockquote><iframe sandbox=\"allow-scripts\" security=\"restricted\" src=\"https:\/\/radwag-merleg.hu\/hu\/product\/workstation-for-pipettes-calibration\/embed\/#?secret=rtv0TYsDZD\" width=\"600\" height=\"338\" title=\"&#8220;WORKSTATION FOR PIPETTES CALIBRATION&#8221; &#8212; Radwag m\u00e9rlegek\" data-secret=\"rtv0TYsDZD\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\" class=\"wp-embedded-content\"><\/iframe><script type=\"text\/javascript\">\n\/*! This file is auto-generated *\/\n!function(c,l){\"use strict\";var e=!1,o=!1;if(l.querySelector)if(c.addEventListener)e=!0;if(c.wp=c.wp||{},c.wp.receiveEmbedMessage);else if(c.wp.receiveEmbedMessage=function(e){var t=e.data;if(!t);else if(!(t.secret||t.message||t.value));else if(\/[^a-zA-Z0-9]\/.test(t.secret));else{for(var r,s,a,i=l.querySelectorAll('iframe[data-secret=\"'+t.secret+'\"]'),n=l.querySelectorAll('blockquote[data-secret=\"'+t.secret+'\"]'),o=0;o<n.length;o++)n[o].style.display=\"none\";for(o=0;o<i.length;o++)if(r=i[o],e.source!==r.contentWindow);else{if(r.removeAttribute(\"style\"),\"height\"===t.message){if(1e3<(s=parseInt(t.value,10)))s=1e3;else if(~~s<200)s=200;r.height=s}if(\"link\"===t.message)if(s=l.createElement(\"a\"),a=l.createElement(\"a\"),s.href=r.getAttribute(\"src\"),a.href=t.value,a.host===s.host)if(l.activeElement===r)c.top.location.href=t.value}}},e)c.addEventListener(\"message\",c.wp.receiveEmbedMessage,!1),l.addEventListener(\"DOMContentLoaded\",t,!1),c.addEventListener(\"load\",t,!1);function t(){if(o);else{o=!0;for(var e,t,r,s=-1!==navigator.appVersion.indexOf(\"MSIE 10\"),a=!!navigator.userAgent.match(\/Trident.*rv:11\\.\/),i=l.querySelectorAll(\"iframe.wp-embedded-content\"),n=0;n<i.length;n++){if(!(r=(t=i[n]).getAttribute(\"data-secret\")))r=Math.random().toString(36).substr(2,10),t.src+=\"#?secret=\"+r,t.setAttribute(\"data-secret\",r);if(s||a)(e=t.cloneNode(!0)).removeAttribute(\"security\"),t.parentNode.replaceChild(e,t);t.contentWindow.postMessage({message:\"ready\",secret:r},\"*\")}}}}(window,document);\n<\/script>\n","thumbnail_url":"https:\/\/radwag-merleg.hu\/wp-content\/uploads\/sites\/3\/2018\/12\/emalog_radwag_pipettes_pipettak_sdkp-1.jpg","thumbnail_width":800,"thumbnail_height":800,"description":"In order to ensure measurement traceability, meet all the requirements resulting from supervision over measuring equipment and to facilitate&nbsp; the process of pipettes calibration RADWAG recommends effective and ergonomic solution for calibrating automatic pipettes conducted by a user - complete workstation for pipettes calibration.  Application: &nbsp;1. Calibration of automatic pipettes from 1&micro;l to 10ml:     with fixed volume    with adjustable volume.  2. Weighing of samples with maximum capacity up to 220g and accuracy d=0,01mg (in standard weighing chamber - pan &oslash; 90mm).  Unit contents:     table for calibration    XA 82\/220.4Y analytical balance    anti-vibration table    probe for temperature, humidity and pressure measurement    probe for water temperature measurement    sink for used water    armrests    LCD monitor    PC with pre-installed software PIPETTES RADWAG    power supply    keyboard and mouse    container for used water   * The pipettes and other small accessories are not included in the unit content."}