{"version":"1.0","provider_name":"Radwag m\u00e9rlegek","provider_url":"https:\/\/radwag-merleg.hu\/hu\/","author_name":"Vogel Krist\u00f3f Istv\u00e1n","author_url":"https:\/\/radwag-merleg.hu\/hu\/author\/kristof\/","title":"Adapters for Pipettes Calibration - Radwag m\u00e9rlegek","type":"rich","width":600,"height":338,"html":"<blockquote class=\"wp-embedded-content\" data-secret=\"agBlE7EQlh\"><a href=\"https:\/\/radwag-merleg.hu\/hu\/product\/adapters-for-pipettes-calibration\/\">Adapters for Pipettes Calibration<\/a><\/blockquote><iframe sandbox=\"allow-scripts\" security=\"restricted\" src=\"https:\/\/radwag-merleg.hu\/hu\/product\/adapters-for-pipettes-calibration\/embed\/#?secret=agBlE7EQlh\" width=\"600\" height=\"338\" title=\"&#8220;Adapters for Pipettes Calibration&#8221; &#8212; Radwag m\u00e9rlegek\" data-secret=\"agBlE7EQlh\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\" class=\"wp-embedded-content\"><\/iframe><script type=\"text\/javascript\">\n\/*! This file is auto-generated *\/\n!function(c,l){\"use strict\";var e=!1,o=!1;if(l.querySelector)if(c.addEventListener)e=!0;if(c.wp=c.wp||{},c.wp.receiveEmbedMessage);else if(c.wp.receiveEmbedMessage=function(e){var t=e.data;if(!t);else if(!(t.secret||t.message||t.value));else if(\/[^a-zA-Z0-9]\/.test(t.secret));else{for(var r,s,a,i=l.querySelectorAll('iframe[data-secret=\"'+t.secret+'\"]'),n=l.querySelectorAll('blockquote[data-secret=\"'+t.secret+'\"]'),o=0;o<n.length;o++)n[o].style.display=\"none\";for(o=0;o<i.length;o++)if(r=i[o],e.source!==r.contentWindow);else{if(r.removeAttribute(\"style\"),\"height\"===t.message){if(1e3<(s=parseInt(t.value,10)))s=1e3;else if(~~s<200)s=200;r.height=s}if(\"link\"===t.message)if(s=l.createElement(\"a\"),a=l.createElement(\"a\"),s.href=r.getAttribute(\"src\"),a.href=t.value,a.host===s.host)if(l.activeElement===r)c.top.location.href=t.value}}},e)c.addEventListener(\"message\",c.wp.receiveEmbedMessage,!1),l.addEventListener(\"DOMContentLoaded\",t,!1),c.addEventListener(\"load\",t,!1);function t(){if(o);else{o=!0;for(var e,t,r,s=-1!==navigator.appVersion.indexOf(\"MSIE 10\"),a=!!navigator.userAgent.match(\/Trident.*rv:11\\.\/),i=l.querySelectorAll(\"iframe.wp-embedded-content\"),n=0;n<i.length;n++){if(!(r=(t=i[n]).getAttribute(\"data-secret\")))r=Math.random().toString(36).substr(2,10),t.src+=\"#?secret=\"+r,t.setAttribute(\"data-secret\",r);if(s||a)(e=t.cloneNode(!0)).removeAttribute(\"security\"),t.parentNode.replaceChild(e,t);t.contentWindow.postMessage({message:\"ready\",secret:r},\"*\")}}}}(window,document);\n<\/script>\n","description":"XA11 pipette calibration adapter enables calibration and\/or verification of piston pipettes by means of a gravimetric method using the XA microbalance. Set content:   base   weighing pan   weighing vessel   evaporation ring   glass chamber with an opening for dosing  Evaporation ring is an integral part of the adapter that increases relative humidity inside the weighing chamber. With this evaporation of the liquid during calibration\/verification is stopped. An integrated weighing pan enables centric loading of the vessel in the weighing chamber. The weighing pan and the vessel are housed in a glass chamber featuring an opening allowing the user to dispense liquid through it, and reducing air drafts. &nbsp; Vessel capacity: 11 ml  &nbsp;  Adapters for Pipettes Calibration  Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table below, which presents the minimum requirements in accordance with ISO 8655-6:2022 standard, enables to select suitable adapter for pipette calibration and respective balance version. The parameters of the balance have been selected so that the expanded uncertainty of measurement in use is less than &frac14; of the maximum permissible error of the test object.  &nbsp;           Nominal volume of apparatus under test&nbsp;   V          Resolution   (d) mg          Repeatability   (s)amg       Recommended balance        &nbsp;     Microbalances     Analytical balances        0,5 &micro;l &le; V &lt; 20 &micro;l        0,001c 0,01d          0,006c, e 0,03d       MYA 21.5Y     XA 6\/21.5Y.M.A   XA 6\/21.5Y.M     XA 21.5Y.M.A   XA 21.5Y.M     XA 21\/52.5Y.M.A   XA 21\/52.5Y.M     XA 53.5Y.M.A   XA 53.5Y.M     &nbsp;        20 &micro;l &le; V &lt; 200 &micro;l     0,01     0,025     XA 52.5Y     XA 110.5Y     XA 82\/220.5Y.A   XA 82\/220.5Y     XA 120\/250.5Y.A   XA 120\/250.5Y        200 &micro;l &le; V &le; 10 ml     0,1     0,2        Adapter for pipette calibration     MY 11     XA 11     XA 11     XA 11     XA 11     XA 17     XA 17     XA 17     XA 100     XA 17     XA 100        Maximum vessel capacity     11 ml     11 ml     11 ml     11 ml     11 ml     17 ml     17 ml     17 ml     100 ml     17 ml     100 ml        Weighing vessel mass     ~ 10 g     ~ 10 g     ~ 10 g     ~ 10 g     ~ 10 g     ~ 11 g     ~ 11 g     ~ 11 g     ~ 65 g     ~ 11 g     ~ 65 g     a&nbsp;&nbsp; The repeatability values, in this table, apply in the volumen determination of a single channel pipette. When a single-channel balance is used for volumen determination of single channel pipettes the repeatability values are double the values of this table. c&nbsp;&nbsp; Single-channel balance. d&nbsp; &nbsp;Multichannel balance, only valid for multi-channel pipettes. Multi-channel balances of 0,01 mg readability may be uses to test multi-channel pipettes with nominla volumes below 20 &micro;l only if the expanded uncertainty in use is less than &frac14; of the maximum permissible systematic error of the test object. e&nbsp; &nbsp;For single-channel pipettes of nominal volumes of less than 2 &micro;l, a balance with repeatability better than the values in the table shall be used so that the expanded uncertainty in use is less than &frac14; of the maximum permissible systematic error of the test object. table {font-size: 12px} td {padding:10px; } tr {text-align:center;} @media (max-width: 800px) { table {font-size: 9px} td {padding: 1px 1px} }"}