{"id":1206,"date":"2026-11-08T00:06:34","date_gmt":"2026-11-07T23:06:34","guid":{"rendered":"http:\/\/10.11.0.201\/product\/sm-5y-a-automatikus-szuszceptometer\/"},"modified":"2026-11-08T18:05:14","modified_gmt":"2026-11-08T17:05:14","slug":"sm-5y-a-automatikus-szuszceptometer","status":"publish","type":"product","link":"https:\/\/radwag-merleg.hu\/en\/product\/sm-5y-a-automatikus-szuszceptometer\/","title":{"rendered":"SM 5Y.A Automatic Susceptometer"},"content":{"rendered":"<div class=\"nowe_opisy_srodek_html_NO\" style=\"display:flex;width:100%;align-items:center;justify-content:center;padding-top:10px;flex-direction:column\">\n<h2 class=\"tytul_h2_NO\" style=\"font-size:28px;color:#000;text-align: center\">\n\t\tSM5Y.A<\/h2>\n<div class=\"kontener_niebieskiej_kreski_NO\" style=\"width:100%;display:flex\">\n<div class=\"niebieska_kreska_NO\" style=\"width: 54px;height: 5px;background: #3a68ff 0% 0% no-repeat padding-box;margin: 30px auto\">\n\t\t\t\u00a0<\/div>\n<\/div>\n<\/div>\n<p>\n\t\u00a0<\/p>\n<p>\n\t\u00a0<\/p>\n<p>\n\t\u00a0<\/p>\n<div class=\"img_left_NO\" style=\"display: flex;flex-direction: row;align-items: center;gap: 10px\">\n<div style=\"width:100%\">\n<img alt=\"\" decoding=\"async\" class=\"obrazek_100_lp_NO\" src=\"https:\/\/radwag-merleg.hu\/en\/wp-content\/uploads\/radwag\/products\/originals\/emalog_radwag_automatic-susceptometers-magnetizat_sm-5y-a-automatic-susceptometer_sm5y-a_wl-101-0428_img-004.jpg\"\/><\/div>\n<div style=\"width:100%\">\n<h2 class=\"tytul_h2_100_NO\" style=\"font-size:28px;color:#000;width:100%\">\n\t\t\tWhat is the Automatic Susceptometer Used for?<\/h2>\n<div class=\"kontener_opisu_NO\" style=\"width:100%;display:flex;align-items:center;justify-content:center\">\n<div style=\"text-align: justify\">\n\t\t\t\tThe instrument is designed to measure the magnetic susceptibility and permanent magnetization of mass standards of class E1 and below with the readability [d] of 1 \u00b5g, in accordance with OIML R111. The SM 5Y.A allows automatic change of magnet polarity and pan level depending on the class of mass standard being tested. Any positive or negative information on the magnetic susceptibility and polarity of the tested mass standard is stored in the database.<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>\n\t\u00a0<\/p>\n<p>\n\t\u00a0<\/p>\n<p>\n\t\u00a0<\/p>\n<div class=\"img_right_NO\" style=\"display: flex;flex-direction: row-reverse;align-items: center;gap: 10px\">\n<div style=\"width:100%\">\n<img alt=\"\" decoding=\"async\" class=\"obrazek_100_lp_NO\" src=\"https:\/\/radwag-merleg.hu\/en\/wp-content\/uploads\/radwag\/products\/originals\/emalog_radwag_automatic-susceptometers-magnetizat_sm-5y-a-automatic-susceptometer_sm5y-a_wl-101-0428_img-005.jpg\"\/><\/div>\n<div style=\"width:100%\">\n<h2 class=\"tytul_h2_100_NO\" style=\"font-size:28px;color:#000;width:100%\">\n\t\t\tFully Automatic Change of Magnet Polarity<\/h2>\n<div class=\"kontener_opisu_NO\" style=\"width:100%;display:flex;align-items:center;justify-content:center\">\n<div style=\"text-align: justify\">\n\t\t\t\tThe program guides you through the process of checking the magnetic properties of the sample tested and then at the appropriate moment it will change the magnet\u2019s polarity and finally display the test result.<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>\n\t\u00a0<\/p>\n<p>\n\t\u00a0<\/p>\n<p>\n\t\u00a0<\/p>\n<div class=\"img_left_NO\" style=\"display: flex;flex-direction: row;align-items: center;gap: 10px\">\n<div style=\"width:100%\">\n<img alt=\"\" decoding=\"async\" class=\"obrazek_100_lp_NO\" src=\"https:\/\/radwag-merleg.hu\/en\/wp-content\/uploads\/radwag\/products\/originals\/emalog_radwag_automatic-susceptometers-magnetizat_sm-5y-a-automatic-susceptometer_sm5y-a_wl-101-0428_img-006.jpg\"\/><\/div>\n<div style=\"width:100%\">\n<h2 class=\"tytul_h2_100_NO\" style=\"font-size:28px;color:#000;width:100%\">\n\t\t\tChanging Measuring Ranges<\/h2>\n<div class=\"kontener_opisu_NO\" style=\"width:100%;display:flex;align-items:center;justify-content:center\">\n<div style=\"text-align: justify\">\n\t\t\t\tThe device has three automatic height levels that determine the distance of the weighing platform from the centre of the magnet. It simultaneously defines the strength of the magnetic field which the mass standard is tested in.<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>\n\t\u00a0<\/p>\n<p>\n\t\u00a0<\/p>\n<p>\n\t\u00a0<\/p>\n<div class=\"img_right_NO\" style=\"display: flex;flex-direction: row-reverse;align-items: center;gap: 10px\">\n<div style=\"width:100%\">\n<img alt=\"\" decoding=\"async\" class=\"obrazek_100_lp_NO\" src=\"https:\/\/radwag-merleg.hu\/en\/wp-content\/uploads\/radwag\/products\/originals\/emalog_radwag_manual-susceptometers-magnetization_sm-mya-5-5y-susceptometer_sm-mya5-5y_wl-101-1084_img-006.jpg\"\/><\/div>\n<div style=\"width:100%\">\n<h2 class=\"tytul_h2_100_NO\" style=\"font-size:28px;color:#000;width:100%\">\n\t\t\tOn the Best Foundations: the 5Y Terminal<\/h2>\n<div class=\"kontener_opisu_NO\" style=\"width:100%;display:flex;align-items:center;justify-content:center\">\n<div class=\"opis_do_lewej_NO\" style=\"width: 100%\">\n<div style=\"text-align: justify\">\n\t\t\t\t\tThe automatic susceptometer was built on the foundation of the 5Y terminal, which stands out among other laboratory terminals because it provides:<\/div>\n<ul>\n<li style=\"text-align: justify\">\n\t\t\t\t\t\t21 CFR Part 11 compliance<\/li>\n<li style=\"text-align: justify\">\n\t\t\t\t\t\tDigital Weighing Auditor<\/li>\n<li style=\"text-align: justify\">\n\t\t\t\t\t\t4+ login methods (password, fingerprint, face recognition, RFID* and combinations)<\/li>\n<li style=\"text-align: justify\">\n\t\t\t\t\t\tHandy Library with measurement history always at the fingertips<\/li>\n<li style=\"text-align: justify\">\n\t\t\t\t\t\tLive Notes\u00a0<\/li>\n<li style=\"text-align: justify\">\n\t\t\t\t\t\tAmbient Light<\/li>\n<li style=\"text-align: justify\">\n\t\t\t\t\t\tWide selection of widgets, databases, working modes and communication interfaces, including hotspot.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>\n\t\u00a0<\/p>\n<p>\n\t\u00a0<\/p>\n<p>\n\t\u00a0<\/p>\n<div class=\"nowe_opisy_srodek_html_ON\" style=\"display:flex;width:100%;align-items:center;justify-content:center;padding-top:10px;flex-direction:column\">\n<h2 class=\"tytul_h2_NO\" style=\"font-size:28px;color:#000;text-align: center\">\n\t\tWhat Interfaces Does the Susceptometer Have? Peripherals You Can Easily Connect to<\/h2>\n<div class=\"kontener_opisu_NO\" style=\"width:100%;display:flex;align-items:center;justify-content:center\">\n<div class=\"opis_NO\" style=\"width:80%;text-align:center\">\n<div style=\"text-align: left\">\n<div>\n\t\t\t\t\tThanks to the 5Y terminal, your susceptometer will connect to:\u00a0<\/div>\n<ul>\n<li>\n\t\t\t\t\t\tComputer and laptop (Ethernet, Wi-Fi\u00ae, USB-A)<\/li>\n<li>\n\t\t\t\t\t\tSmartphone and tablet (hotspot)<\/li>\n<li>\n\t\t\t\t\t\tPrinter (Ethernet, Wi-Fi\u00ae, USB-A)<\/li>\n<li>\n\t\t\t\t\t\tBarcode scanner (USB-A)<\/li>\n<li>\n\t\t\t\t\t\tAdditional screen (HDMI)<\/li>\n<li>\n\t\t\t\t\t\tAny PC software (RADWAG communication protocol)<\/li>\n<li>\n\t\t\t\t\t\tSpreadsheet (USB-C, Free Link)<\/li>\n<li>\n\t\t\t\t\t\tKeyboard\u00a0<\/li>\n<li>\n\t\t\t\t\t\tMouse.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>\n\t\u00a0<\/p>\n<p>\n\t\u00a0<\/p>\n<p>\n\t\u00a0<\/p>\n<p style=\"text-align: right\">\n\t* RFID ISO\/IEC 14443 Type A, 13.56 MHz<\/p>\n<p>\n\t\u00a0<\/p>\n<p>\n\t\u00a0<\/p>\n","protected":false},"excerpt":{"rendered":"<p>SM5Y.A \u00a0 \u00a0 \u00a0 \u00a0 What is the Automatic Susceptometer Used for? The instrument is designed to measure the magnetic susceptibility and permanent magnetization of mass standards of class E1 and below with the readability [d] of 1 \u00b5g, in accordance with OIML R111. The SM 5Y.A allows automatic change of magnet polarity and pan<br \/><a class=\"more-link\" href=\"https:\/\/radwag-merleg.hu\/en\/product\/sm-5y-a-automatikus-szuszceptometer\/\"><br \/>\n        Read More<span class=\"screen-reader-text\"> &#8220;SM 5Y.A Automatic Susceptometer&#8221;<\/span><\/a><\/p>\n","protected":false},"featured_media":8806,"template":"","meta":[],"product_brand":[],"product_cat":[94],"product_tag":[],"class_list":["post-1206","product","type-product","status-publish","has-post-thumbnail","product_cat-automatic-susceptometers-magnetization","badges-style-2","first","instock","taxable","shipping-taxable","product-type-simple"],"gallery_images":[5952,5953],"_links":{"self":[{"href":"https:\/\/radwag-merleg.hu\/en\/wp-json\/wp\/v2\/product\/1206","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/radwag-merleg.hu\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/radwag-merleg.hu\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/radwag-merleg.hu\/en\/wp-json\/wp\/v2\/media\/8806"}],"wp:attachment":[{"href":"https:\/\/radwag-merleg.hu\/en\/wp-json\/wp\/v2\/media?parent=1206"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/radwag-merleg.hu\/en\/wp-json\/wp\/v2\/product_brand?post=1206"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/radwag-merleg.hu\/en\/wp-json\/wp\/v2\/product_cat?post=1206"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/radwag-merleg.hu\/en\/wp-json\/wp\/v2\/product_tag?post=1206"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}