MA 5Y.IC Moisture Analyzers

Code: N/A

Compare products
Quote list
Views17

Compare configurations

SpecificationMA 110.5Y.IC Moisture Analyzer
WL-304-0049
MA 110.5Y.IC.NS Moisture Analyzer
WL-304-0050
MA 110.5Y.IC.WH Moisture Analyzer
WL-304-0051
MA 200/1.5Y.IC Moisture Analyzer
WL-304-0052
MA 200/1.5Y.IC.NS Moisture Analyzer
WL-304-0053
MA 200/1.5Y.IC.WH Moisture Analyzer
WL-304-0054
MA 210.5Y.IC Moisture Analyzer
WL-304-0055
MA 210.5Y.IC.NS Moisture Analyzer
WL-304-0056
MA 210.5Y.IC.WH Moisture Analyzer
WL-304-0057
MA 50.5Y.IC Moisture Analyzer
WL-304-0058
MA 50.5Y.IC.NS Moisture Analyzer
WL-304-0059
MA 50.5Y.IC.WH Moisture Analyzer
WL-304-0060
MA 50/1.5Y.IC Moisture Analyzer
WL-304-0061
MA 50/1.5Y.IC.NS Moisture Analyzer
WL-304-0062
MA 50/1.5Y.IC.WH Moisture Analyzer
WL-304-0063
Maximum capacity [Max]110 g110 g110 g200 g200 g200 g210 g210 g210 g50 g50 g50 g50 g50 g50 g
Readability [d]1 mg1 mg1 mg0,1 mg0,1 mg0,1 mg1 mg1 mg1 mg1 mg1 mg1 mg0,1 mg0,1 mg0,1 mg
Tare range-110 g-110 g-110 g-200 g-200 g-200 g-210 g-210 g-210 g-50 g-50 g-50 g-50 g-50 g-50 g
OIML ClassIIIIIIIIIIIIIIIIIIIIIIII
Verification unit [e]10 mg10 mg10 mg1 mg1 mg1 mg10 mg10 mg10 mg10 mg10 mg10 mg1 mg1 mg1 mg
Heating moduleIR emittermetal heaterhalogenIR emittermetal heaterhalogenIR emittermetal heaterhalogenIR emittermetal heaterhalogenIR emittermetal heaterhalogen
Drying temperature rangeMax 160 °CMax 160 °CMax 250 °CMax 160 °CMax 160 °CMax 250 °CMax 160 °CMax 160 °CMax 250 °CMax 160 °CMax 160 °CMax 250 °CMax 160 °CMax 160 °CMax 250 °C
Moisture content readability0,001 %0,001 %0,001 %0,0001 %0,0001 %0,0001 %0,001 %0,001 %0,001 %0,001 %0,001 %0,001 %0,0001 %0,0001 %0,0001 %
Maximum sample weight110 g110 g110 g200 g200 g200 g210 g210 g210 g50 g50 g50 g50 g50 g50 g

MA110.5Y.IC.WH

 

Do you need a moisture analyzer that not only determines moisture or dry matter content with impressive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages?

 

If so, learn about the functionality of the ELLIPSIS series of moisture analyzers:

 

 

 

 

 

It Dries in 4 Ways

The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step.
 
  • The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content.
  • The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather.
  • You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent.
  • The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally.

 

 

 

What Drying Temperature Should I Set?

The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally.
 
The maximum drying temperature on the MA 5Y.IC.WH Moisture Analyzer is 250 °C.

 

 

 

How Do I Finish the Drying? In 4 Ways

The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined.
  • Automatic mode
    You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end.
  • Manual mode
    You terminate the measurement yourself by pressing the STOP button.
  • Time-defined mode
    The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage!
  • User-defined mode
    When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure.

 

 

 

10-Inch Display

Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity.

 

 

 

Illustration of facial recognition

Uncompromising User Verification

For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user.

 

 

 

Balance terminal with a coloured status light

Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User

The light colour will tell you about status, process results, procedures, or alerts.

 

 

 

Hotspot

Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer.

 

 

 

Entering a text note on the balance touchscreen

Live Note – Note Down Your Conclusions

It’s the first time you can add a text memo to a measurement series or procedure report. These can be, for example, assumptions, reminders or questions that can be returned to at any time.

 

 

 

21 CFR Part 11

Do you work in the pharmaceutical industry? Do you need a digital signature We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11.
  • Full data security
  • Electronic signatures
  • Validations
  • Electronic records
  • Audit trails

 

 

 

Modbus TCP/IP communication illustrated with binary data

Modbus TCP/IP

is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. 
 
A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds.

 

 

 

* RFID ISO/IEC 14443 Type A, 13.56 MHz

 

 

 

Maximum capacity [Max]110 g
Readability [d]1 mg
Tare range-110 g
Weighing pan dimensionsø90, h= 8 mm
Operating temperature+10 – +40 °C
Protection classIP 43
Packaging dimensions W x D x H540×610×470 mm
OIML ClassII
Verification unit [e]10 mg
Net weight7 kg
Gross weight14 kg
Power supply100 – 120 V AC 50/60 Hz or 200-240 V AC 50/60 Hz
Communication interface2×USB-A, USB-C, RS 232 (COM3), HDMI, Ethernet, Wi-Fi, Hotspot
Display10″ graphic colour touchscreen
Finish mode4 modes (automatic, manual, time-defined, user-defined)
Drying method4 drying profiles (standard, fast, step, mild)
Maximum sample height20 mm
Heating modulehalogen
Drying temperature rangeMax 250 °C
Moisture content repeatability±0,05 % (sample ~ 2 g), ±0,01 % (sample ~ 10 g)
Moisture content readability0,001 %
Maximum sample weight110 g
Additional functionssample traceability
Heating module power450 W
Power consumption6 W
Adjustmentinternal (automatic)
Leveling systemsemi-automatic – LevelSENSING
Display mode%D, %M, %R, g
Weighing chamberautomatic
Drying temperature control1 or 2 punktowa, zależno from profilu suszenia, (wyposażenie dodatkowe: termometr kontrolny GT105k-12/Z)
Drying temperature adjustment3 punktowa adjustacja w zdefiniowanych temperaturach, wartości programowalne (wyposażenie dodatkowe: termometr kontrolny GT105k-12/Z)
Mass indication controlExternal mass standard 50g, 100g, 200g, depending on the type of moisture analyzer (additional equipment)
Moisture content indication controlCertified MV Test Set (additional equipment)
Delivery componentsMoisture Analyzer, disposable pan x 10, cross-shaped holder, drying pan handle, weighing pan shield, fabric dust cover, power cord
  • Air density correction
  • ALIBI Memory
  • Ambient conditions monitoring
  • Animal weighing
  • Automatic sliding door
  • Autotest
  • BMI
  • Checkweighing
  • Density determination
  • Differential weighing
  • Dosing
  • Dry mass determination
  • Drying modes
  • Formulation
  • GLP Procedures
  • Internal battery
  • IR sensors
  • Labelling
  • Mass for titrator
  • Microwave drying
  • Moisture content analysis
  • Moveable range
  • Newton unit measurement
  • Packaged Goods Control
  • Parts counting
  • Peak hold
  • Percent Weighing
  • Pipettes Calibration
  • Plus/Minus Control
  • Replaceable unit
  • Samples drying
  • Statistical Quality Control
  • Statistics
  • Totalizing
  • Transactions
  • Under-pan weighing
  • Wi-Fi
  • Additional information line
  • Colour Touch Screen
  • Communicationinterfaces
  • Data exchange throughUSB storage devices
  • Electroniclevel indicator
  • Ergonomic Mechanical Design
  • Extra function keys
  • Grill pan
  • Infraredproximity sensors
  • Interfaces
  • Levelling System
  • Modes
  • Portability
  • SMARTLab
  • USB at the Balance Front
  • CE
  • Verification
  • 2 years warranty

Product documentation

Additional documents

MA X2.A Moisture analyser with an Auto-opened chamber Open video
Measurement of Samples of High Moisture Content Open video
MA X2.A Moisture Analyzer Unpacking and Installation (Tutorial) Open video
New AS and PS 5Y Balances – Autotest (Tutorial) Open video
Video 5 Open video
Video 6 Open video
Video 7 Open video
Video 8 Open video
Video 9 Open video
Video 10 Open video
Video 11 Open video
Wi-Fi连接,轻松打印 Open video
Video 13 Open video
Video 14 Open video
Video 15 Open video