C315.4P2 Beam Scales

Code: N/A

Compare products
Quote list
Views10

Compare configurations

SpecificationC315.4P2.1500.C Beam Scale
WP-240-0001
C315.4P2.2000.C1 Beam Scale
WP-240-0002
C315.4P2.2000.C2 Beam Scale
WP-240-0003
C315.4P2.3000.C Beam Scale
WP-240-0004
C315.4P2.4000.C1 Beam Scale
WP-240-0005
C315.4P2.4000.C2 Beam Scale
WP-240-0006
C315.4P2.600.C Beam Scale
WP-240-0007
C315.4P2.6000.C1 Beam Scale
WP-240-0008
C315.4P2.6000.C2 Beam Scale
WP-240-0009
C315.4P2.1500/3000.C Beam Scale
WP-240-0010
Maximum capacity [Max]1500 kg2000 kg2000 kg3000 kg4000 kg4000 kg600 kg6000 kg6000 kgNot available
Minimum load10 kg20 kg20 kg20 kg40 kg40 kg4 kg40 kg40 kgNot available
Readability [d]500 g1 kg1 kg1 kg2 kg2 kg200 g2 kg2 kgNot available
Tare range-1500 kg-2000 kg-2000 kg-3000 kg-4000 kg-4000 kg-600 kg-6000 kg-6000 kgNot available
Weighing pan dimensions2 pcs 1,2 m2 pcs 2 m2 pcs 2,5 m2 pcs 1,2 m2 pcs 2 m2 pcs 2,5 m2 pcs 1,2 m2 pcs 2 m2 pcs 2,5 mNot available
Operating temperature-10 – +40 °C-10 – +40 °C-10 – +40 °C-10 – +40 °C-10 – +40 °C-10 – +40 °C-10 – +40 °C-10 – +40 °C-10 – +40 °CNot available
Relative humidity10% – 85% RH no condensation10% – 85% RH no condensation10% – 85% RH no condensation10% – 85% RH no condensation10% – 85% RH no condensation10% – 85% RH no condensation10% – 85% RH no condensation10% – 85% RH no condensation10% – 85% RH no condensationNot available
Protection classIP 65 construction, IP 67 cell, IP 43 terminalIP 65 construction, IP 67 cell, IP 43 terminalIP 65 construction, IP 67 cell, IP 43 terminalIP 65 construction, IP 67 cell, IP 43 terminalIP 65 construction, IP 67 cell, IP 43 terminalIP 65 construction, IP 67 cell, IP 43 terminalIP 65 construction, IP 67 cell, IP 43 terminalIP 65 construction, IP 67 cell, IP 43 terminalIP 65 construction, IP 67 cell, IP 43 terminalNot available
OIML ClassIIIIIIIIIIIIIIIIIIIIIIIIIIINot available
Verification unit [e]500 g1 kg1 kg1 kg2 kg2 kg200 g2 kg2 kgNot available
Max readability for non-verified scale500 gNot availableNot availableNot availableNot availableNot available200 gNot availableNot availableNot available
Optional interfacesRS232RS232RS232RS232RS232RS232RS232RS232RS232Not available
Power supply100 – 240 V AC 50/60 Hz and battery100 – 240 V AC 50/60 Hz and battery100 – 240 V AC 50/60 Hz and battery100 – 240 V AC 50/60 Hz and battery100 – 240 V AC 50/60 Hz and battery100 – 240 V AC 50/60 Hz and battery100 – 240 V AC 50/60 Hz and battery100 – 240 V AC 50/60 Hz and battery100 – 240 V AC 50/60 Hz and batteryNot available
Operation time on batteriesmax 8hmax 8hmax 8hmax 8hmax 8hmax 8hmax 8hmax 8hmax 8hNot available
Cable length3 m + 5 m3 m + 5 m3 m + 5 m3 m + 5 m3 m + 5 m3 m + 5 m3 m + 5 m3 m + 5 m3 m + 5 mNot available
Communication interfaceRS232RS232RS232RS232RS232RS232RS232RS232RS232Not available
Display4,3” LCD (backlit)4,3” LCD (backlit)4,3” LCD (backlit)4,3” LCD (backlit)4,3” LCD (backlit)4,3” LCD (backlit)4,3” LCD (backlit)4,3” LCD (backlit)4,3” LCD (backlit)Not available
Power consumption max.5 W5 W5 W5 W5 W5 W5 W5 W5 WNot available
Device dimensions W x D x H1200×120×85 mm2000×120×105 mm2500×120×105 mm1200×120×85 mm2000×120×155 mm2500×120×155 mm1200×120×85 mm2000×120×155 mm2500×120×155 mmNot available
Scale mass with indicator37 kg53 kg65 kg37 kg90 kg105 kg37 kg90 kg133 kgNot available
Beam scales C315.4P2 series is stable and proved four load cells weighing solution with more versatile application than standard pallet scales. The adjustable distance between the beams (up to 5 meters) enables fitting the C315.4P2 scales to different loads (cases, long bars, heavy sections). The load to be weighed can be placed on the beams by a standard fork-lift truck.

Beam scales C315.4P2 series is manufactured in mild steel powder coated version. Optionally, the number of beams in a scale can be increased to 4. Beam scales features handles for easy transporting the scales to its place of use.

The scales comes standard with an indicator PUE C315 series featuring backlit LCD display and function buttons. The indicator is installed on a long cable.
The scale is powered from mains 230V AC, RS 232 interface comes standard.

Scales is available in dual range version on surcharge.
Maximum capacity [Max]1500 kg
Minimum load10 kg
Readability [d]500 g
Tare range-1500 kg
Weighing pan dimensions2 pcs 1,2 m
Operating temperature-10 – +40 °C
Relative humidity10% – 85% RH no condensation
Protection classIP 65 construction, IP 67 cell, IP 43 terminal
OIML ClassIII
Verification unit [e]500 g
Max readability for non-verified scale500 g
Optional interfacesRS232
Power supply100 – 240 V AC 50/60 Hz and battery
Operation time on batteriesmax 8h
Cable length3 m + 5 m
Communication interfaceRS232
Display4,3” LCD (backlit)
Power consumption max.5 W
Device dimensions W x D x H1200×120×85 mm
Scale mass with indicator37 kg
  • Air density correction
  • ALIBI Memory
  • Ambient conditions monitoring
  • Animal weighing
  • Automatic sliding door
  • Autotest
  • BMI
  • Checkweighing
  • Density determination
  • Differential weighing
  • Dosing
  • Dry mass determination
  • Drying modes
  • Formulation
  • GLP Procedures
  • Internal battery
  • IR sensors
  • Labelling
  • Mass for titrator
  • Microwave drying
  • Moisture content analysis
  • Moveable range
  • Newton unit measurement
  • Packaged Goods Control
  • Parts counting
  • Peak hold
  • Percent Weighing
  • Pipettes Calibration
  • Plus/Minus Control
  • Replaceable unit
  • Samples drying
  • Statistical Quality Control
  • Statistics
  • Totalizing
  • Transactions
  • Under-pan weighing
  • Wi-Fi
  • Additional information line
  • Colour Touch Screen
  • Communicationinterfaces
  • Data exchange throughUSB storage devices
  • Electroniclevel indicator
  • Ergonomic Mechanical Design
  • Extra function keys
  • Grill pan
  • Infraredproximity sensors
  • Interfaces
  • Levelling System
  • Modes
  • Portability
  • SMARTLab
  • USB at the Balance Front
  • 2 years warranty
  • Verification
  • CE